No header here
GatesAir
1-1
Intraplex Products
Section 1 – Introduction
1.1 Manual Scope
This manual is the primary reference covering the configuration, installation, and operation of the
Intraplex CrossConnect products. The manual has eight sections:
●
Section 1 – “Introduction” provides an overview of this manual and T1 CrossConnect Systems and
Servers and their components.
●
Section 2 – “Theory of Operation” provides descriptions of the T1 CrossConnect Systems and
Servers’ concepts and applications.
●
Section 3 – “Installation and Wiring” provides information for the installing and wiring T1
CrossConnect Systems and Servers.
●
Section 4 – “Mapping Basics” provides an introduction to the concepts of time slot mapping and
switching with examples of six system configurations with ISiCL and IntraGuide sample maps.
●
Section 5 – “Configuration Using Intraplex IntraGuide” provides an introduction to IntraGuide use
for configuring and controlling T1 CrossConnect Systems and Servers.
●
Section 6 – “Configuration Using ISiCL” provides an introduction to ISiCL (Intraplex Simple
Command Language) use for configuring and controlling T1 CrossConnect Systems and Servers.
●
Section 7 – “CM-95 Operation” provides an introduction to the operating T1 CrossConnect Systems
and Servers.
●
Section 8 – “Specifications” provides operational, physical, and environmental specifications for T1
CrossConnect Systems and Servers.
1.2 Product Overview
The Intraplex DCS-9500 and DCS-9530 CrossConnect Systems and the Intraplex DCS-9560 and DCS-
9565 CrossConnect Servers provide switching of multiple payload channels over standard 1.536 Mbps
T1 circuits as well as time slot cross-connect capabilities. The DCS-9560 and DCS-9565 also feature
versatile multiplexer capabilities that provide access to voice, data, video, and high-fidelity audio
payloads on the T1. Key features include
●
Interface with as many as six T1 ports
●
Local access, termination, and multiplexing of individual user payload channels, up to 48 time
slots
●
Programmable T1 line protection switching
●
Individual time slot routing among all T1 ports
●
Automatic protection switching on any of the T1 ports
●
Eight time slot grooming maps that can be configured to switch based on T1 port failure, external
TTL inputs, or ASCII command strings
●
Versatile system timing options to connect to almost any network
●
Reliability, small size, low power consumption, and configuration flexibility
●
Compliance with ESF and SF T1 frame formats
●
Support for both B8ZS and AMI T1 line codes
●
Convenient built-in diagnostic capability
●
Optional redundant power supply (DCS-9530, DCS-9560, and DCS-9565)
●
Optional LAN, wideband data, synchronous and asynchronous data, voice, video, and high fidelity
program audio channel modules (DCS-9560 and DCS-9565)
●
Remote configuration through IntraGuide, the graphical user interface, or Intraplex Simple