T1 CrossConnect Installation & Operation Manual
5 – Configuration Using IntraGuide
Version 2
5-10
GatesAir
Intraplex Products
If you want to set a selected map to ON for testing purposes, such as to clear a circuit, click the option
for that map at
Select Active Map
. Setting the map to ON disables error detection and switching.
After the circuit is cleared, you should set the map to OFF by clicking the
Automatic
option.
You can also perform map switching through external contacts. At
External Switching
, you can
select a check box to enable any of the maps for this kind of switching. You then have to close a
contact switch (on the MA-251A adapter module) to actually trigger the external map switch.
To change the port and time slot settings in a map, perform these steps:
1.
In the Configuration pane, on the
Map Control
tab (Figure 5-11), click
Edit Maps
. A progress
dialog box indicates that IntraGuide is communicating with the DCS and reading in the current
map configurations. Then the
Edit CrossConnect Maps
window appears. Figure 5-12 shows this
window with the initial defaults.
Figure 5-12. Edit CrossConnect Maps
2.
Select the map to edit from the
Edit Map
list.
3.
To change the setting for one or two time slots
a.
Right-click a time slot.
b.
On the right-click menu, click
Edit Time Slot
.
c.
Select the port and time slot that you want the current port and time slot to map to.
d.
Click
OK
.
4.
To change settings for groups of adjacent time slots
a.
Select the time slots in a
Receive
column.
b.
Drag and drop the selected time slots to move them to a
Transmit
column.
5.
To save the new map configuration in a file, click
Write File
.
6.
Click the map number, and click
OK
.
7.
Enter a file name in the
Save As
dialog box, and click
Save
.