Intraplex NetXpress IP Multiplexer
4—System Configuration and Operation
Version 3.05
4-2
GatesAir, Inc.
Intraplex Products
4.2 NetXpress Configuration Procedures
After you confirm your equipment order and make any needed installations (Section 3.3 –
Intraplex
NetXpress Equipment Unpacking and Installation
) perform these configuration procedures.
4.2.1
Connect and Log On to Access NetXpress Home Page
1.
Connect a PC directly to the Ethernet MGMT port on the MIU-201 or MIU-202.
Note:
The MIU automatically senses the media type and you may use a cable wired as straight-
through or a cross-over cable for this connection. Auto-negotiation is the default and your PC must
also be set up to auto-negotiate its IP connection.
2.
Configure the IP address on the PC to be 192.168.1.10 using netmask 255.255.255.0.
3.
Open your Web browser and access the NetXpress multiplexer using the default IP Address
192.168.1.1 for MGMT.
4.
A prompt appears requiring you to type a user name and password to access the NetXpress Web
Interface. Type the default
User name
= “admin” and
Password
= “admin”.
5.
Click OK
.
If the credentials are accepted, the
NetXpress Home
page appears (Figure 4-1).
Figure 4-1. NetXpress Home Page
When you initially connect to the NetXpress system, this
Home
page appears, showing an overview of
the modules installed in the multiplexer. The
NetXpress Release
system software revision number
appears in the upper left of the window. Compare this installed version with the available updates
mentioned in Section 4.1 –
Software Downloads
to assure you are running the most recent version. The
downloadable update packages also include installation instructions.
4.2.2
View System Mode
The operating
System
Mode
also appears in the upper left of the
Home
page.
4.2.2.1 System Mode:
E1
In this configuration the two electrical interfaces (“T1-E1 A” and “T1-E1 B”) communicate using E1 line
coding, formats and date rates (2.048Mbps) and all four of the NetXpress busses (TDM1A, TDM1B,
TDM2A and TDM2B) run at 2.048Mbps. Installed TDM Channel Modules also need to be E1 compatible in
order to operate properly. E1 mode does not support VF-15, VF-16A, VF-25, or VF-28 voice modules.
Summary of Contents for Intraplex NetXpress
Page 2: ......
Page 54: ...No header here 3 16 GatesAir Inc Intraplex Products This page is left blank intentionally...
Page 146: ...No header here 4 92 GatesAir Inc Intraplex Products This page is left blank intentionally...
Page 154: ...No header here 6 4 GatesAir Inc Intraplex Products This page is left blank intentionally...
Page 163: ...No header here GatesAir Inc 7 9 Intraplex Products This page is left blank intentionally...