72
GATES.COM
reTrofiTTing a CriMper
Gates GC20 Cortex
3.
Finalize the location of the sensor by moving the upper hose clamp up or
down on the tie rod, so that the body of the sensor is approximately 1/8
inch above the lip of the channel. Once you have the distance correct,
double check that the body of the sensor is parallel to the crimper tie
rod, and firmly tighten to secure the final location.
This distance and
orientation is important.
If the sensor is installed incorrectly, the crimper
won’t operate or you’ll get an error during the set-up calibration process.
In either situation, come back to this step and verify the installation of the
sensor.
Install upper mount
so that the distance
between sensor
body and channel
= 1/8" +/- 1/16"
Channel
Figure 83: Install the upper mounting clamp