68
GATES.COM
reTrofiTTing a CriMper
Gates GC20 Cortex
11.
Remove swivel fitting from the crimper top plate.
Swivel fitting
Figure 79: Remove swivel fitting from the crimper
ADD NEW COMPONENTS TO THE CRIMPER
1.
Separate the loosely connected adapters between the T-adapter and the
solenoid. Install the T-adapter to the top plate and tighten. You may need to
remove the support bracket for clearance. (Figure 80A)
2.
Reconnect the adapter from Port 2 on the solenoid to the bottom of the
T-brace. Orient the solenoid so the adapter in Port 1 is parallel to the back
of the crimper and tighten the connection between the T-adapter. Re-install
support bracket if removed in step 1. (Figure 80B)
Support
Bracket
Location
T-Bracket
Pressure Line
Connection
Pressure Line
Connection-
Back of
T-Adapter
Adapter in
Port 2- Connect
to bottom of
T-Adapter
Adapter in
Port 1-
Return Hose
Connection
Adapter
location to
separate the
selenoid for
installation
Figure 80A: T-adapter install
Figure 80B: Solenoid install