![Gasboy 9822Q Installation & Operation Manual Download Page 38](http://html1.mh-extra.com/html/gasboy/9822q/9822q_installation-and-operation-manual_568212038.webp)
GASBOY Series 9820Q
32
MDE-4339 9820Q ASTRA Installation/Operation • July 2004
ATC Information Sheet
By activating the magnet located at the opposite side of the totalizer, various items will appear on the
display:
1.
Volume Display
Displays uncompensated volume
0023.43
2.
Probe Temperature Display
Displays probe temperature in Celsius only
0 23.2
3.
Flow Reat Display
Displays flow rate (in LPM only)
189.2
4.
Software Version Display
Displays software version number
1.30
5.
ATC Status Display
Displays ATC Status
842.2
On the status display, the rightmost digit (2) indicates whether or not temperature compression is enabled,
and if so, what product is being dispensed. 0=temperature compensation enabled; 1=product is gasoline
and compensation is enabled; 2=product is diesel and compensation is enabled.
On the status display, the leftmost digits (842) are error indicators which are blank when the
corresponding error condition is not active. When any of these digits are displayed, their meanings are:
8=temperature probe fault is detected; 4=pulser error occurred; 2=exceptional reset was detected.
Setting the DIP Switches
#
Use
Setting
1
Product 1
ON=Diesel; OFF=Gasoline
2
Product 2
ON=Diesel; OFF=Gasoline
3
Not Used
4
Not Used
5
Pulser Multiplier
ON=9850; OFF=9852/9853
6
# of Probes
ON=2, OFF=1
7
Pulser Adder
ON=9840
8
ATC
ON=ATC on; OFF=ATC off
Summary of Contents for 9822Q
Page 1: ...Series 9820Q ASTRA Installation Operation Manual MDE 4339 formerly 035090...
Page 18: ...GASBOY Series 9820Q 12 MDE 4339 9820Q ASTRA Installation Operation July 2004...
Page 22: ...GASBOY Series 9820Q 16 MDE 4339 9820Q ASTRA Installation Operation July 2004...
Page 32: ...GASBOY Series 9820Q 26 MDE 4339 9820Q ASTRA Installation Operation July 2004...