IMPORTANT WARNINGS AND SAFEGUARDS

Gasoline and petroleum products are flammable.  To avoid injury or death to persons or damage to equipment or
property, follow these listed warnings and other warnings and precautions outlined in this manual when installing, using,
or working around this equipment.  Check with GASBOY Technical Services for compatibility of liquids with pump
materials.

TURN OFF AND LOCK OUT ALL POWER TO PUMP BEFORE PERFORMING SERVICE, MAINTENANCE OR IN THE EVENT

OF A FUEL SPILL.

All products must be installed by a
qualified installer and used in
conformance with all building, fire, and
environmental codes and other safety
requirements applicable to its
installation and use, including, but not
limited to, NFPA 30, NFPA 30A, NFPA
395 & NFPA 70.  A qualified installer is
familiar with fuel systems installations
under the above stated building, fire,
and environmental codes and other
safety requirements for the particular
type of installation.

This product is only part of a fuel
dispensing system and additional
equipment and accessories, such as,
but not limited to, breakaway
connectors, shear valves, pressure
regulators, flow limiters, and other
safety devices may be necessary to
meet the applicable codes.

For maximum safety, we recommend
that all employees be trained as to the
location and procedure for turning off
power to the entire system.  Instructions
regarding proper operation of the
equipment along with the appropriate
safety warnings should be posted in
plain view at the fuel island.

Before performing service or
maintenance (including changing of fuel
filters or strainers) or in the event of a
fuel spill, turn off and lock out all power
to the system.  In battery-powered
pumps, disconnect power source.  In
submersible pump applications, turn off
and lock out power at the master panel
and close any impact valves to the
submersible pump and any other
dispensers which use that submersible
pump.  AC power can feed back into a
shut-off dispenser when dispensers
share a common submersible pump or
starter relay.  Also block islands so no
vehicles can pull up to the dispenser
when the dispenser is being worked on.

DO NOT

 use Teflon tape for any pipe

threads in the product.

DO NOT

 use consumer pumps for

pumping fuel or additives into aircraft.

DO NOT

 use commercial pumps for

direct fueling of aircraft without filters
and separators necessary to ensure
product purity.

DO NOT

 use where sanitary design is

required (for food products for human
consumption) or with water-based
liquids.

DO NOT

 smoke near the pump or when

using the pump.

DO NOT

 use near open flame or

electrical equipment which may ignite
fumes.

DO NOT

 permit the dispensing of

gasoline or other petroleum products
into a vehicle with its motor running.

DO NOT

 permit the dispensing of

gasoline or other petroleum products
into unapproved containers or into
approved containers in or on vehicles
including trucks.  All containers must be
filled on the ground to prevent static
discharge.  Always use Approved and
Listed hoses and nozzles with electric
pumps and dispensers.

DO NOT

 block open the nozzle in any

manner.  Nozzles shall conform to UL
and NFPA code requirements for
attended or unattended service.

DO

 ensure that the pump is equipped

with proper filters based on the product
being dispensed and its intended use.

DO

 wear safety goggles and protective

clothes when dispensing any liquid
which may be potentially harmful or
hazardous.

DO

 keep all parts of body and loose

clothing clear of belts, pulleys, and
other exposed moving parts at all times.

DO

 require washing and changing of

clothes if fuel is spilled on a person or
his/her clothing.  Keep away from open
flames, sparks, or people smoking.

DO

 provide a receptacle for catching

product from pump/meter when
servicing.

DO

 clean up product spills on the

driveway.  Turn off and lock out all
power prior to cleanup.

DO

 insure pump is properly grounded.

DO

 insure hose is compatible with fluid

being dispensed.

DO

 inspect hose, nozzle, and pump on

a regular basis for wear, damage, or
other conditions which may create a
safety or environmental hazard.

DO

 make sure all pipe threads are

properly cut and the inside reamed to
remove burrs.  Use UL classified
gasoline-resisting compound on all
joints of gasoline handling piping.
Sealing compound must also be
resistant to Gasohol (Ethanol and
Methanol).  Use gasoline-resistant pipe
compound on male threads only; pipe
compound used on female threads can
be squeezed into the supply line where
it can enter the product stream and
become lodged in the pump or meter.

DO

 ensure that junction box covers are

in place and properly tightened.  Mating
surfaces between the box and cover
must be free of dirt, nicks, and
scratches.  All unused entries into the
junction box must be properly plugged

Summary of Contents for 9822Q

Page 1: ...Series 9820Q ASTRA Installation Operation Manual MDE 4339 formerly 035090...

Page 2: ...A 9152A 9153A 9800A 9840A 9850A 9852A 9853A 9140 G 70 52 AM G 70 150 AE Balance Vapor Recovery VaporVac MH6418 Power operated Transfer Pump Models 25 26 27 28 72 72S 72SP 72X 73 and 182 4997 9822A 982...

Page 3: ...aft DO NOT use commercial pumps for direct fueling of aircraft without filters and separators necessary to ensure product purity DO NOT use where sanitary design is required for food products for huma...

Page 4: ...rt 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the device is operated in a commercial environment This equipment generates uses and...

Page 5: ...22Q 9823Q 7 011930 Base Layout Models 9822Q 9823Q 8 011884 Base Layout Models 9822Q 9823Q 9 011885 Base Layout Models 9822Q 9823Q 10 011885 Base Layout Models 9822Q 9823Q 11 3 Control Lines 13 Purpose...

Page 6: ...izer 33 Electronic Totalizer 33 Mechanical Totalizer 34 Operating Sequence 34 Nozzle Locking 35 6 Start Up and Test 36 Installation Completion Checklist 36 Start Up 37 Post Start Up Tests 37 Voltage 3...

Page 7: ...ivery rate varies depending upon installation conditions and added accessories Both models of the 9820Q offer electronic registration of the quantity dispensed NOTE NFPA regulations do not allow tank...

Page 8: ...connect to Gasboy CFN equipment Battery backup for display of last transaction and capture of remnant pulse count in the event of a power failure Mechanical totalizer Dual stage solenoid valve A work...

Page 9: ...w In order to provide the highest level of safety to you your employees and customers we recommend that all employees be trained as to the location and procedure for turning off power to the entire sy...

Page 10: ...es are required to the nozzle hook or boot assembly when using vapor recovery nozzles Please note that the vapor recovery nozzles approved for use are the short spout type The following nozzles and ho...

Page 11: ...ngth of hose less nozzles and fittings Register Minimum Radius Indicates the closest the register assembly can be to the specified starting point any closer than this distance may allow hose to touch...

Page 12: ...GASBOY Series 9820Q 6 MDE 4339 9820Q ASTRA Installation Operation July 2004 Typical Installation See page 19 for cable requirements...

Page 13: ...Installation MDE 4339 9820Q ASTRA Installation Operation July 2004 7 011931 Base Layout Models 9822Q 9823Q View 1 Pumping Unit Assembly...

Page 14: ...GASBOY Series 9820Q 8 MDE 4339 9820Q ASTRA Installation Operation July 2004 011930 Base Layout Models 9822Q 9823Q View 2 Register Assembly...

Page 15: ...Installation MDE 4339 9820Q ASTRA Installation Operation July 2004 9 011884 Base Layout Models 9822Q 9823Q Optional Post...

Page 16: ...GASBOY Series 9820Q 10 MDE 4339 9820Q ASTRA Installation Operation July 2004 011885 Base Layout Models 9822Q 9823Q Side and Rear Brackets View 1...

Page 17: ...Installation MDE 4339 9820Q ASTRA Installation Operation July 2004 11 011885 Base Layout Models 9822Q 9823Q Side and Rear Brackets View 2...

Page 18: ...GASBOY Series 9820Q 12 MDE 4339 9820Q ASTRA Installation Operation July 2004...

Page 19: ...tied into the ground bus strip of the panel We recommend the neutral and ground bus strips be bonded together unless prohibited by local codes Micro Feed The Micro Feed is a 115 VAC 230 VAC Int l inp...

Page 20: ...any conduit or chassis metal mis wired or be connected to any equipment requiring more than stated maximum allowable current If these restrictions are not followed damage to the CPU PCB will occur Ph...

Page 21: ...peration July 2004 15 RS 485 When the dispensing unit includes the optional RS 485 interface RS 485 lines are provided This interface allows the user to connect a GASBOY CFN Series System or TopKAT sy...

Page 22: ...GASBOY Series 9820Q 16 MDE 4339 9820Q ASTRA Installation Operation July 2004...

Page 23: ...he motor should be on a separate circuit and installed on a 20 to 30 AMP breaker depending on the motor size and or the voltage setting 6 Install an emergency power cutoff In addition to circuit break...

Page 24: ...pped from the factory with motors wired according to the specifications given on the order as to kind of current frequency and voltage Very often on installation it becomes necessary to change the ori...

Page 25: ...lows the pulser wires to run in the same conduit as the AC wiring for the short distance between the pumping unit and the register assembly Belden 89418 is rated as follows Gas and Oil resistant insul...

Page 26: ...fit Manual C35628 for details The GASBOY Warranty will not apply to any dispenser in which the AC and DC wires are run in the same conduit J Box or wireway except as noted The GASBOY Warranty will not...

Page 27: ...Wiring MDE 4339 9820Q ASTRA Installation Operation July 2004 21 Terminal Block ID The terminal blocks shown below are located in the register assembly...

Page 28: ...parate relay to prevent false triggering of the authorization signal 3 If the PUMP MOTOR line is controlled by a fuel management system using solid state relays a resistor assembly must be installed b...

Page 29: ...Installation Operation July 2004 23 023866 Wiring Diagram Models 9822Q 9823Q Domestic 115 230 VAC WARNING Failure to follow the correct wiring diagram and all the listed notes and precautions may resu...

Page 30: ...r assembly must be installed between the Pump Motor Feed line and Neutral to prevent false triggering of the authorization input The resistor assembly is 30K OHM 10 Watt P N C06683 for 230 VAC interna...

Page 31: ...stallation Operation July 2004 25 023867 Wiring Diagram Models 9822Q 2 9823Q 2 International 230VAC WARNING Failure to follow the correct wiring diagram and all the listed notes and precautions may re...

Page 32: ...GASBOY Series 9820Q 26 MDE 4339 9820Q ASTRA Installation Operation July 2004...

Page 33: ...iew This section describes the operation of the pump It shows how to access the electronic components how to set the internal switches the optional battery back up power supply how to view and reset t...

Page 34: ...iar with the location of some key components as well as the various switch selectable operating modes 1 Unlock and remove the front panel Remove the two screws located at the top of the door assembly...

Page 35: ...to reflect the communication rate of the GASBOY RS 485 pump loop open for 9600 baud or closed for 1200 baud The GASBOY CFN system and TopKAT communicate at 9600 baud SW1 2 Mode If the 9820 is control...

Page 36: ...Series 1000 TopKAT mechanical and all non GASBOY systems When open the 9800 ignores the Control Feed line required setting for CFN TopKAT electronic or no fuel system SW1 7 Totalizers This switch sho...

Page 37: ...ured by setting the switches as shown in the chart at right The pulse rate represents pulses per gallon PPG domestic or pulses per liter PPL international For domestic units the pulse rate can be up t...

Page 38: ...tes whether or not temperature compression is enabled and if so what product is being dispensed 0 temperature compensation enabled 1 product is gasoline and compensation is enabled 2 product is diesel...

Page 39: ...on the power supply View Reset Totalizer Electronic Totalizer The 9820Q stores a running quantity total This electronic totalizer works independent of the optional mechanical totalizer that may be in...

Page 40: ...of the pumping unit Operating Sequence The exact sequence of events that occurs during the operation of the pump is determined by various switch settings inputs and the user A typical transaction is e...

Page 41: ...ructions below 1 Insert the nozzle onto the hook assembly with the nozzle tip inside of the boot 2 Slide the rear bracket of the nozzle hook assembly upward until the holes near the bottom of the nozz...

Page 42: ...ecured 3 All plumbing must be complete and tight All liquid carrying lines must be checked for leaks 4 When DC pulse output lines are used in the pump for connecting to GASBOY fuel management systems...

Page 43: ...rrected before testing is continued It is good practice to take voltage readings while the pump is operating on bypass and also while making a delivery Any voltage drop in excess of 10 during either o...

Page 44: ...nt in the prover to match the display turn counter clockwise to increase the amount in the prover to match the displayed Moving the wheel one hole position changes the calibration by 2 3 cubic inch pe...

Page 45: ...thorized Parts Should excessive wear rust or corrosion of parts cause inefficient operation it is always best to replace them immediately but if you want the best results and continuity of the Underwr...

Page 46: ...removing the cartridges to prevent contamination of both the soil and the electrical components within the cabinet Adjust the Belts With the proper care belts will give exceptionally good service A l...

Page 47: ...date of original invoice The warranty covers parts only Keytrol The Keytrol is warranted against defects in material and workmanship for one year from date of installation or 24 months from date of or...

Reviews: