3.2.1
Materials Required but Not Supplied
The following installation materials are required, but are not available from Garmin:
•
Insulated stranded wire (MIL-W-22759/34 or MIL-W-22759/16)
•
Shielded wire (MIL-C-27500 cable utilizing M22759/34 wire (SD) and ETFE jacket or MIL-C-
27500 cable utilizing M22759/16 wire (TE) and ETFE jacket )
•
Push/pull manually resettable circuit breakers.
Aircraft with 14 VDC or 28 VDC electrical systems require one of the following circuit breakers:
o
MS26574-5 (5 Amp, G5, GMU 11, GAD 29/29B)
Or
o
Garmin P/N 355-00010-08 (5 Amp, G5, GMU 11, GAD 29/29B)
•
Cable ties or lacing cord
•
MS25036 ring terminals (for grounding and circuit breaker connections)
•
Shield terminators (AS83519/1-X or AS83519/2-X or equivalent)
•
Silicone fusion tape, A-A-59163 (MIL-I-46852C or equivalent)
•
Environmental splice (AS81824/1-X, where X=size or equivalent)
•
Flat braid, 1/16” (AA59569F36T0062 or equivalent)
•
Tubing and fittings are required to connect pitot and static air to the G5. Pitot and Static
plumbing parts are aircraft specific, see Section 4.1.5.
•
120Ω CAN cable, see section 3.4.5 for more information. There are two options for this wire.
o
GigaFlight Connectivity P/N GF120-24CANB-1
▪
GigaFlight contact information:
GigaFlight Connectivity Inc.
6180 Industrial Ct.
Greendale, WI 53129
United States
Toll Free: +1 (844) 303-1093
Phone: +1 (414) 488-6320
Email:
o
Carlisle IT P/N CAN24TST120(CIT),
▪
Carlisle IT contact information:
Carlisle Interconnect Technologies
5300 W. Franklin Drive
Franklin, WI 53132
United States
Toll Free: +1 (800) 327-9473
Phone: +1 (414) 421-5300
•
15Ω (±1% or better), 0.5W resistors qualified to MIL-R-10509 or MIL-PRF-26 (i.e.
RN65D15R0FB14, RN65C15R0BB14).
Note:
The ±1% tolerance is a minimum requirement and