Section 2
Installation
National Codes Requirements:
•
The type of gas for which the grill is equipped is
stamped on the serial plate mounted on the lower left
corner of the right panel. Connect a grill to the gas type
stamped on the data plate only.
•
The installation must conform to the National Fuel Gas
Code ANSI Z223.1-1998 or latest edition, NFPA No. 54 –
latest edition and National Electrical Code ANSI/NFPA
70-1990 or latest edition and/or local code to assure
safe and efficient operation. In Canada, the installation
must comply with CSA B149.1 and local codes where
applicable.
•
In Canada, electrical connection must comply with
applicable sections of the Canadian Electrical Code,
C22.1 - 1990, latest edition, “Safety Standard for
Installation, Part 1” and C22.2- No. O-M 1982 latest
edition.
Installation store responsibilities:
•
The installation shall be made with a connector that
complies with the Standard for Connectors for Move-
able Gas Appliances, ANSI Z21.69/CSA 6.16, and quick-
disconnect device that complies with the Standard for
Quick Disconnect Devices for Use with Gas Fuel, ANSI
Z21.41/CSA 6.9.
•
The front Casters on the appliance are equipped with
brakes to limit the movement of the appliance without
placing any strain on the connector or quick disconnect
device or its associated piping.
•
Please be aware: required restraint is attached to a
bracket, (which is located on the front of the grill,
underneath, closest to the gas connection) and if
disconnection of the restraint is necessary, be sure
to reconnect the device after the appliance has been
returned to its original position.
RESTRAINING CABLE
FRONT CASTER WITH
BRAKE TO SECURE GRILL
BLOCKING SECURE
TO CONCRETE WALL
OR STUD
STUD
•
“Adequate clearance must be provide for air opening
into the combustion chamber, and for proper servicing”
•
Not intended to be installed adjacent to combustible
walls or on combustible floors.
•
Ensure grill has been installed by a competent trained
installation person.
•
Ensure store readiness of utilities, product & personnel.
•
Contacting your local Garland Factory Authorized
Service Center for a startup date.
•
Participate in the startup to ensure a successful startup
and familiarity with the grill.
•
Conduct training with your crew personnel to ensure
maximum utilization of the grill. Once the installation
is complete as per the procedures below, a factory
authorized service company MUST startup the grill
according to Garland Commercial Ranges startup
standards.
Restraining device installation Procedure
1. Shutoff main gas line valve and disconnect the quick-
disconnect gas line device before the following
installation .
2. Attach the bracket to a stud in the wall.
3. Locate the area in the
frame on front of the grill
underneath, to place the
eye-bolt. Closest to the gas
connection
4. For model one (1) platen grill gas. Discard nylon
lock nut of the eye-bolt and screw it underneath
of the front panel above the gas line (Figure
A), tighten eye-bolt jam nut to secure it in place.
5. For model two & three (2&3) platen grill gas. Slide
the eye-bolt through the hole and place the nylon
lock nut on the inside frame and tighten securely
(Figure B).
attached to the wall
spring loaded
hook
appliance
loop
eye-bolt