User Guide
EdgeLens® Focus | INT10G12xxBP | 4.22.1
Open
If selected and power is lost to the unit. The traffic will switch between the
network ports.
Closed
If selected and power is lost to the unit. The traffic will go down.
5. LFP
If enabled and link is lost on one of the network ports. The TX will be disabled on
the other network port. The RX for both network ports remain on.
Figure 21 Load Balance Tap Mode (LFP)
6. Reverse Bypass
If enabled and the inline appliance port(s) fail, loss of link or heartbeats, defined
by the bypass threshold value, 1-4. The TX will be disabled on both of the
network ports. The RX for both network ports remain on.
Figure 22 Load Balance Tap Mode (Reverse Bypass, Bypass Threshold=2)
7. Bypass Threshold
The bypass threshold determines how many inline appliance port(s) may fail,
loss of link or heartbeats, before the tap switches to bypass.
8. Select Accept to save updates. Save must additionally be selected on the Bypass Taps panel.
9. Select Cancel to return the Bypass Taps panel.
Garland Technology | 716.242.8500 | www.garlandtechnology.com