User Guide
EdgeLens® Focus | INT10G12xxBP | 4.22.1
Bypass Tap Name
1. Select the Pencil icon for the desired tap.
The Tap Name panel will be displayed.
2. Enter the name.
3. Remove the name by placing the cursor in the name panel, backspace or delete the current name.
4. Select the Check to save updates.
5. Select Cancel to return the Bypass Taps panel.
Heartbeat Settings
The following configuration options may be displayed or modified.
No. Of Lost HB Packets
Heartbeats per Second
1. Select Settings on the Bypass Taps panel.
The Configure Heartbeat Settings panel will be displayed with the current configuration.
2. Enter the No. Of Lost HB Packets. Default is 10.
This is the number of heartbeats that must be lost on an inline appliance port before any
tap will remove the inline appliance from the load balance group.
3. Enter the Heartbeats per Second. Default is 10.
This is the number of heartbeats per second applied to the inline appliance ports for all taps.
4. Select Save to save updates.
5. Select Cancel to return the Bypass Taps panel.
Configure Load Balance Tap Mode
1. Edit the tap mode by placing the cursor on any tap and double-press the left mouse button.
The Tap panel will be displayed.
2. Place the cursor on the Load Balance Mode Select option. Select with the left mouse button.
Drag the Load Balance option to the blue box and release.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2022 Garland Technology, LLC. All rights reserved.