User Guide
EdgeLens® Focus | INT10G12xxBP | 4.22.1
This is the number of heartbeats per second sent on the inline appliance ports for all entities.
4. Select the Tap Mode.
Active
Allows the tap to automatically switch from inline to bypass if an issue occurs
with all entities A, B, C and D inline appliance port(s), loss of link or heartbeats
based on the bypass threshold value for each entity. Each entity A, B, C and D
are in bypass. The network port pairs 1-2 will be connected together. When the
issue with any entity A, B, C or D inline appliance port(s) is resolved, have link
and heartbeats, the tap will automatically switch back to inline.
Figure 24 ATLB2 Chained Tap Mode (Inline)
Figure 25 ATLB2 Chained Tap Mode (Bypass)
Force Bypass If selected, the tap will switch the traffic between the network port pairs
1-2 with no regard for the entity inline appliance port(s), link or heartbeats.
Typically used during maintenance activities.
Figure 26 ATLB2 Chained Tap Mode (Force Bypass)
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2022 Garland Technology, LLC. All rights reserved.