User Guide
EdgeLens® Focus | INT10G12xxBP | 4.22.1
4. Select the Fail Mode.
Open
If selected and power is lost to the unit. The traffic will switch between the
network ports.
Closed
If selected and power is lost to the unit. The traffic will go down.
5. LFP
If enabled and link is lost on one of the network ports. The TX will be disabled on
the other network port. The RX for both network ports remain on.
Figure 6 Default Tap Mode (LFP)
6. Reverse Bypass
If enabled and the inline appliance port(s) fail, loss of link or heartbeats. The TX
will be disabled on both of the network ports. The RX for both network ports
remain on.
Figure 7 Default Tap Mode (Reverse Bypass)
7. Select Accept to save updates. Save must additionally be selected on the Bypass Taps panel.
8. Select Cancel to return the Bypass Taps panel.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2022 Garland Technology, LLC. All rights reserved.