User Guide
EdgeLens® Focus | INT10G12xxBP | 4.22.1
Bypass Tap Name
1. Select the Pencil icon for the desired tap.
The Tap Name panel will be displayed.
2. Enter the name.
3. Remove the name by placing the cursor in the name panel, backspace or delete the current name.
4. Select the Check to save updates.
5. Select Cancel to return the Bypass Taps panel.
Heartbeat Settings
The following configuration options may be displayed or modified.
No. Of Lost HB Packets
Heartbeats per Second
1. Select Settings on the Bypass Taps panel.
The Configure Heartbeat Settings panel will be displayed with the current configuration.
2. Enter the No. Of Lost HB Packets. Default is 10.
This is the number of heartbeats that must be lost on any inline appliance port before any
tap will switch from the primary inline appliance to the secondary inline appliance to bypass.
3. Enter the Heartbeats per Second. Default is 10.
This is the number of heartbeats per second applied to the primary inline appliance and
secondary inline appliance ports for all taps.
4. Select Save to save updates.
5. Select Cancel to return the Bypass Taps panel.
Configure Primary-Secondary Tap Mode
1. Edit the tap mode by placing the cursor on any tap and double-press the left mouse button.
The Tap panel will be displayed.
2. Place the cursor on the Primary-Secondary Mode Select option. Select with the left mouse button.
Drag the Primary-Secondary option to the blue box and release.
3. Select the red X to remove.
4. Place the cursor on the Inline Appliance option. Select with the left mouse button. Drag the Inline
Appliance option to the blue box and release.
5. Select the red X to remove.
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2022 Garland Technology, LLC. All rights reserved.
31