background image

 

USER GUIDE

 

 
 

 

www.kontron.com 

 

 

 

 

KSwitch D1 UGPD Unmanaged Gigabit 
PoE Ethernet Switch  

Doc. Preliminary User Guide, Rev. 0.9 

Doc. ID: 1068-1429  

 

 

Summary of Contents for kontron KSwitch D1 UGPD

Page 1: ...USER GUIDE www kontron com KSwitch D1 UGPD Unmanaged Gigabit PoE Ethernet Switch Doc Preliminary User Guide Rev 0 9 Doc ID 1068 1429...

Page 2: ...KSwitch D1 UGPD Unmanaged Gigabit PoE Ethernet Switch Preliminary User Guide Rev 0 9 www kontron com 2 This page has been intentionally left blank...

Page 3: ...tation or warranty that such application will be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general...

Page 4: ...Risk Applications is entirely at your risk To minimize the risks associated with your products and applications you should provide adequate design and operating safeguards You are solely responsible f...

Page 5: ...on contacts by visiting https www kontron com support and services kontron europe and asia support contact support Customer Service As a trusted technology innovator and global solutions provider Kont...

Page 6: ...utions indicated and or prescribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title inform that the electronic boards and th...

Page 7: ...ation of piggybacks Serious electrical shock hazards can exist during all installation repair and maintenance operations on this product Therefore always unplug the power cable and any other cables wh...

Page 8: ...hort circuits and damage the batteries or conductive circuits on the product Lithium Battery Precautions If your product is equipped with a lithium battery take the following precautions when replacin...

Page 9: ...e components used are capable of being recycled Final disposal of this product after its service life must be accomplished in accordance with applicable country state or local laws or regulations WEEE...

Page 10: ...ods 14 3 Shipment and Packaging 15 3 1 Packaging 15 3 2 Unpacking 15 3 3 Scope of Delivery 15 3 4 Accessories 15 3 5 Product Identification Type Label 17 4 Features 18 4 1 Faceplate Features 19 4 1 1...

Page 11: ...ardware Specification 32 Table 9 Environmental Specification 33 Table 10 Certification Compliance 33 Table 11 Mechanical Specification 33 Table 12 Electrical Specification 34 Table 13 List of Acronyms...

Page 12: ...this user guide visit Kontron s KSwitch Industrial Ethernet Switches at https www kontron com products systems ethernet solutions This user guide provides an overview of the switch s features and ava...

Page 13: ...ted Power Source LPS and Power Source PS2 of UL IEC 62368 1 Only products or parts that meet the requirements for Power Source PS1 of UL IEC 62368 1 may be connected to the product s available interfa...

Page 14: ...ding techniques are necessary precautions to prevent damage Always take the following precautions 1 Transport ESD sensitive parts in ESD safe containers such as boxes or bags until they arrive at an E...

Page 15: ...mportant information for handling the switch 5 Check the content for visible shipping damage If you notice any shipping damage or inconsistencies between the content and the original order contact Kon...

Page 16: ...Switch Preliminary User Guide Rev 0 9 www kontron com 16 Product Name Description RK4U 19 Rack Mount Kit 4U Enables DIN Rail switch to be installed in a 4U rack WK97 Wall mount L brackets and screws P...

Page 17: ...www kontron com 17 3 5 Product Identification Type Label Figure 1 Type Label 1 Model full name 2 Series name 3 Part Number PN with bar code 4 Revision 5 Serial Number SN with barcode 6 Production dat...

Page 18: ...Ethernet industrial PoE injector in a ruggedized design that meets the IEEE 802 3af at standard with 15 4 30 60 Watts output Figure 2 KSwitch D1 UGPD PoE Injector Key features are Up to 4 ports with P...

Page 19: ...es not detect a PoE device connected to the PD port power is not sourced and Ethernet data communications are permitted PSB and PSE provide a Gigabit downlink to supply further PoE compatible devices...

Page 20: ...LED 3 RJ45 Copper Link Act Speed LEDs Table 5 Indicator LEDs LED Name Indicator Color Condition B Link Act On Blue PoE on PSB port is working Off PoE on PSB port is not working Off PoE on PSE port is...

Page 21: ...Wire length 3 m 9 84 ft maximum Wire strip length 7 mm 0 28 in When DC IN is connected to a 24 VDC to 48 VDC DC power supply DC OUT can be used as a power line to supply 12 VDC and 1 A Figure 5 DC IN...

Page 22: ...upply 12 VDC and 1 A 4 1 4 DC Power Jack The switch can be powered from an external AC DC power adapter with jack input range 24 VDC to 48 VDC using the DC IN power jack Figure 7 DC IN Power Jack conn...

Page 23: ...d 60 W PoE The PD requires standard CAT5e cables or better with a maximum length of 100 m Figure 8 PD Input Port PD IN supports IEEE 802 3 af at PoE 4 1 6 Ground Connector The switch must be grounded...

Page 24: ...r side of the 4 port variant supports a PSE port with indicator LED Figure 10 Rear Side 4 port PSE power output 30 W 600 mA 4 3 Left Side Features The DIP Switch selects the PoE port s input source an...

Page 25: ...tsinks The heatsinks absorb the heat produced by the internal components and transfers the heat by dissipating the heat into the ambient environment Take care not to obstruct the airflow over the heat...

Page 26: ...DIN Rail clip enabling the orientation of the DIN Rail clip to be changed by 180 Sets of mounting holes on the right and left side enable installation of wall mount brackets For mounting information s...

Page 27: ...autions before handling the switch Only authorized well trained professionals should be allowed to access the restricted access location Access should be controlled by the authority responsible for th...

Page 28: ...on a flat surface or wall use the Wall Mount Kit with wall mount L brackets The wall mount L brackets fasten to the mounting holes on the left and right sides of the switch Figure 14 Wall Mount L Brac...

Page 29: ...ount L brackets and screws to ensure the switch is secured properly 3 Fasten the wall mount L brackets to the switch using the screws provided 4 Mount the switch to a wall or flat smooth surface by in...

Page 30: ...guarantee disconnection using a separate cut off fixture 6 1 Connecting to DC Terminal Block To connect to an external 24 VDC to 48 VDC DC power supply and turn on and perform the following 1 Connect...

Page 31: ...m 31 6 3 Connecting to PD Input Port To connect the switch using PD and turn on perform the following 1 Connect a ground wire to the ground connector 2 Insert the cable s CAT 5e or better cable to the...

Page 32: ...to Negotiation Duplex 10 100 1000 Mbps speed auto negotiation full and half duplex Cable Requirements Cat5e or better Cable Length 100 meters max PoE Ports Output Power IEEE 802 3af at PoE 15 4W 30W 6...

Page 33: ...4 EN 61000 6 2 and EN 55035 Safety UL IEC EN 62368 1 FCC According to requirements of 47 CFR FCC Part 15 Subpart B Class A rules and regulations and ANSI C63 4 2014 rules to limit the potential of ha...

Page 34: ...ith adequate power Protection Reverse power protection Only connect the switch to an external power supply providing the voltage type AC or DC and the input power max current specified on the Kontron...

Page 35: ...ge sufficiently Failure to observe this required off state time may mean that parts of the switch or peripherals work incorrectly or suffer a reduction of MTBF The minimum off state time to allow inte...

Page 36: ...ontains no user serviceable parts For maintenance and repair return the switch the Kontron see Chapter 9 1 Returning Defective Merchandise Restricted Access The switch s intended use is in a Restricte...

Page 37: ...ated warranty period Follow these steps before returning any product to Kontron 1 Visit the RMA Information website http www kontron com support and services support rma information Download the RMA R...

Page 38: ...e statutory accident liability obligations in the event of damage caused to the product due to failure to observe the following General safety instructions for IT equipment within this user guide Warn...

Page 39: ...Diode LPS Limited Power Source MAC Media Access Control MDI Medium Dependent Interface MDIX Medium Dependent Interface cross over MIB Management Information Base MLD Multicast Listener Discovery MSTI...

Page 40: ...and Industry 4 0 applications With its standard products and tailor made solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications f...