![background image](http://html1.mh-extra.com/html/garland/g12-2tcg/g12-2tcg_installation-and-operation-manual_3597401004.webp)
Part # 4527947 (02/09/10)
Page 4
DIMENSIONS AND SPECIFICATIONS
11-3/4"
[300mm]
21-1/2"
[545mm]
23-5/8"
[600mm]
1-1/2"
[39mm]
OF GAS
MANIFOLD
35-1/2"
[902mm]
9-5/8"
[245mm]
G24-4TCG
G12-2TCG
13-1/2"
[343mm]
21-3/8"
[544mm]
14-3/8"
[365mm]
25"
[634mm]
29-3/8"
[747mm]
4"
[100mm]
COOKING
SURFACE
7-3/8"
[186mm]
G12-2TCG & G24-4TCG
OF GAS
MANIFOLD
Open Burner Ratings
BTU/hr (kW/hr)
Natural Gas
Propane
32,000 (9 .37)
25,000 (7 .32)
Manifold Operating Pressure
"w .c . (Mbar)
Natural Gas
Propane
4 .5 (11 .2)
10 .0 (25)
Minimum Supply Pressure
"w .c . (Mbar)
Natural Gas
Propane
7 .0 (17 .4)
11 (27 .5)
Clearance
Non Combustible Material
Rear
Sides
0"
0"
Combustible Material
Rear
Sides
6" (150mm)
14" (356mm)
Model
Description
Input; BTU/Hr
Natural Gas
Propane
G12-2TCG
11-3/4” (300mm) 2 open top burner counter model
64,000
50,000
G24-4TCG
23-5/8” (600mm) 4 open top burner counter model
128,000
100,000
Gas input ratings shown for installations up to 2000 ft ., (610m) above sea level .