USER GUIDE

  

EdgeSafe 40G Bypass Modular Network TAP  |  M40GBP

 

 

Version 1.6                                                                                                                         Page 114 of 159 

Garland Technology reserves the right to make changes without further notice to any products or data herein to improve reliability, function or design. 

Confidential -This document is 

Garland Technology

.'s property. This document may not be copied, duplicated and transferred to electronic or mechanized 

media or used for any other purpose, including any part thereof or attachment thereto, except as authorized in advance and in writing by 

Garland Technology.

 

 

7.2  Starting web interface 

The M40GBP  WEB interface can be access  from any WEB browser. To connect to the M40GBP WEB 
interface use the following address on your WEB browser: 

 

If https enabled: “https://device_ip_address/index.html.en” 

 

If https disabled:  “http:// device_ip_address/index.html.en” 

Where device_ip_address – M40GBP Ethernet Management port IP address.  
Note:  

 

If  the  WEB  interface  is  inactive  more  than  the  web_expired_time,  a  login  screen  will  be 

prompt. 

 

Most web application fields contain context help. 

 

The new settings in the WEB interface will take affect only after clicking the “

apply

” button. 

 

7.3  Login  

 

On the login screen type the user name and the password. (Default user name is “admin”. Default 
password is “gtadmin1”). 
User name should include minimum 5 symbols and can be up to 64 symbols.  
Password should include minimum 8 symbols and can be up to 128 symbols.  
The first user that will be logged in to the WEB interface will get all the rights (Control /monitor) of the 
Web interface application, the next users will not able to control device, they will be able only to 
monitor the M40GBP parameters. 
When first user will be logged off from the WEB interface, the next user will receive his rights and will 
be able to (Control /monitor) the WEB interface.

 

Summary of Contents for EdgeSafe M40G1AC

Page 1: ...hnology EdgeSafeTM 40G Bypass Modular Network TAP User Guide M40G1AC M40GMSBP M40GSSBP M10GMS2BP M10GSS2BP New York Texas Germany Australia Office 716 242 8500 support garlandtechnology com garlandtec...

Page 2: ...d THE GARLAND TECHNOLOGY LOGO are trademarks of Garland Technology LLC in the U S and other countries The use of any of these trademarks without Garland Technology prior written consent is strictly pr...

Page 3: ...copied duplicated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Ga...

Page 4: ...23 3 2 1 Bypass Switch 1U Host System LEDs Switches Specifications 23 3 3 M40GBP MODULE 25 3 3 1 M40GMSBP4 M40GSSBP4 LED and Connector Specifications 25 3 4 M40GBP MODULE 26 3 4 1 M10GMS2BP M10GSS2BP...

Page 5: ...6 16 6 Delete skective bypass filter del_slct_bypass 50 6 16 7 Set selective bypass on off set_slct_bypass on off 50 6 16 8 Get selective bypass on off set_slct_bypass on off 50 6 16 9 Get selective...

Page 6: ...OG 71 6 49 1 Get remote log state 71 6 49 2 Set remote log state 71 6 49 3 Get remote log server IP 71 6 49 4 Set remote log server IP 71 6 50 NTP NETWORK TIME PROTOCOL 72 6 50 1 Get NTP state 72 6 50...

Page 7: ...view all entries use the command get_snmp_entry entry_index all 91 6 62 2 add_snmp_entry Add new SNMP entry up to 11 different entries 92 6 62 3 Select SNMP entry sel_snmp_entry 93 6 62 4 Set get_snm...

Page 8: ...SNMP trap account 131 7 11 9 SNMP trap account allow to add remove view additional destinations for SNMP traps SNMP trap control 131 7 12 LOG FILE PAGE 133 7 12 1 Log file control area 133 7 12 2 Remo...

Page 9: ...k mounting 148 10 2 TFTP SERVER INSTALLATION AND CONFIGURATION 149 10 2 1 Windows TFTP server installation and configuration 149 10 2 2 Linux TFTP server installation and configuration 149 10 3 NET SN...

Page 10: ...rnet Multimode Fiber 40GBase SR4 and 40 Gigabit Single mode fiber 40GBase LR4 network standards Each 40G Bypass module includes two MPO LC ports for network ports and two QSFP ports for the attached i...

Page 11: ...le 1U Switch 40G LR4 SMF Single Segment Bypass and 40G SR4 MMF Single Segment Bypass 90 240 VAC Auto Select US cable M10GMS2BP Dual segment 10G 1G Gigabit SR SX fiber Intelligent Bypass Switch SR SX M...

Page 12: ...the heartbeat packets and transmits the heartbeat packet to the in line Monitor Network appliance port the Monitor Network appliance receives the heartbeat packets and transmits is to its other port b...

Page 13: ...Garland Technology s property This document may not be copied duplicated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment there...

Page 14: ...port bridges the heartbeat packet As long as the M40GBP detects the heartbeat packet is received from the Monitor Network appliance it will maintain the Normal In Line mode state In event of applicat...

Page 15: ...ic continues to flow through the network ports and is not diverted to the monitor ports When the Monitor link is restored it transmits back the heartbeat packet the M40GBP will then set to Inline mode...

Page 16: ...s property This document may not be copied duplicated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authori...

Page 17: ...licated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Techn...

Page 18: ...This document may not be copied duplicated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in adv...

Page 19: ...uplicated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Tec...

Page 20: ...uplicated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Tec...

Page 21: ...ted and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Technolog...

Page 22: ...chnology s property This document may not be copied duplicated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except a...

Page 23: ...link on the other network port as well 2 14 Restore from active expire state The M40GBP supports manual and auto restoring from heartbeat expiration event 2 15 Heartbeat active mode When heartbeat ac...

Page 24: ...1 M40G1AC M40G1AC with 3 M40GBP modules Figure 10 M40G1AC front panel 3 2 M40G1AC Management panel Figure 11 M40G1AC front panel 3 2 1 Bypass Switch 1U Host System LEDs Switches Specifications LEDs FR...

Page 25: ...module1 power on Light Green M2 module2 power on Light Green 2 M3 module3 power on Light Green BACK One bi color LED indication that integrated on each power supply module Power Switch On Green color...

Page 26: ...mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Technology 3 3 EdgeSafe 40G module Figure 12 E...

Page 27: ...hanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Technology 3 4 EDGESAFE 10G module Figure 13 Edge...

Page 28: ...eliability function or design Confidential This document is Garland Technology s property This document may not be copied duplicated and transferred to electronic or mechanized media or used for any o...

Page 29: ...h Installation 5 1 Rack mount the M40GBP The M40GBP is a rack mounting ready box 5 2 Connecting Power to the 220V 110V M40GBP unit 5 2 1 Connect two power cables to the M40GBP The PWR led s on the fro...

Page 30: ...yperTerminal to connect to the CLI interface to in order manage the M40GBP 4 Set the following terminal communication parameters 115200 default or 9600 if set by CLI command 8 bits no parity 1 stop bi...

Page 31: ...pt as authorized in advance and in writing by Garland Technology 6 Command line interface CLI Login to the command line interface CLI using the Rs232 management port or the Ethernet management port Th...

Page 32: ...kt get set_session_exp_time get set_mgmt_port_state get set_hb_tx_dir get set_hb_fail get set_remote_log_server_ip get set_remote_log_state get set_ntp_state get set_ntp_server_ip send_ntp_request get...

Page 33: ...t_dev_prop The M40GBP can contain up to 3 different modules 40G and 10G The command get_dev_prop return the info regarding the current installed modules Examples On the above example only one 40G bypa...

Page 34: ...the heartbeat packet received from the monitor ports the M40GBP will switch to Active Bypass or TAP or Linkdrop mode according to the predefined settings of the Heartbeat Expiration state When heartb...

Page 35: ...Bypass TAP TAPI12 TAPA TAPAI1 TAPAI2 TAPAI12 or Linkdrop In order to check the current mode of the Active bypass circuitry use the command get_bypass_mode In order to change set the Active bypass cir...

Page 36: ...link 2PL The M40GBP supports two ports link When enabled on if one of the network ports link fails it drops the link on the other network port Two ports link is disabled off by default Example 6 8 Mon...

Page 37: ...for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Technology 6 9 hb_interval hb_interval The M40GBP generates a heartbeat...

Page 38: ...active switch expire state To secure reliable detection of Application failure the hb_holdtime value should be at least 3 times the hb_interval parameter value default 20 min 10 max 50000 The hb_hold...

Page 39: ...te When the M40GBP does not receive the heartbeat packet within the hb_holdtime time it will set the Active Bypass circuitry to the state that was set by the hb_exp_state Bypass Tap Tapi12 Tapa Tapai1...

Page 40: ..._hb_restore The M40GBP support automatic or manual heartbeat restore after a heartbeat expiration event The default value for the en_act_hb_restore is ON When the en_act_hb_restore is ON the M40GBP wi...

Page 41: ...TX error detection rx_tx_err_mode The M40GBP can place itself into Bypass or Linkdrop in case it detects RX TX errors on the Monitor ports or on the Network ports Example M40GBP get_rx_tx_err_mode rx...

Page 42: ...on each bypass segment The HB packet can return on a different segment than the one that it was sent Heartbeat failutre not due to link failure will cause the LAG segments to switch to Bypass mode A...

Page 43: ...embers creates new LAG and add lag members to existing lag Ctrl lag1m1s1 10g M40GBP get_lag lag1 lag hb active on lag state inline application state unknown minimum working members 1 members m1s1 m1s2...

Page 44: ...set_lag_min_work_members A link failure by one of the LAG segments will cause all the LAG segments to switch to Bypass mode only of the number of avliable links is the LAG falls below the threshold Th...

Page 45: ...ule segment module segment delete LAG members lag_name LAG name 1 20 characters module module number 1 3 segment segment number 1 2 Ctrl lag1m1s1 10g M40GBP get_lag lag1 lag hb active on lag state inl...

Page 46: ...6 16 Selective bypass filters The Selective Bypass filter provides the ability to filter and Bypass packet between Net0 Net1 based on IP MPLS tag VLAN id It is possible to set the filter to specific...

Page 47: ...including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Technology 6 16 1 White list redirect Network Device Switch Router Transparent Network Appli...

Page 48: ...y other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Technology 6 16 2 Black list redirect Network Device Switch Router Transparen...

Page 49: ...or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Technology 6 16 3 Black list drop Network...

Page 50: ...versa Filtered traffic goes according to bypass mode When black drop list is enabled all traffic except filtered dropped Filtered traffic goes according to bypass mode xxx_up direction from NET0 to N...

Page 51: ..._mask group del_slct_bypass ip_up ip_down redir drop src_ip src_ip_mask n a dst_ip dst_ip_mask n a src_port n a src_port_mask n a dst_port n a dst_port_mask n a group del_slct_bypass mac_up mac_down r...

Page 52: ..._bypass x_range get_slct_bypass x_range first last on off group get_slct_bypass x_range first last on off group get selective bypass rules without parameters displays all rules for segment rule_list d...

Page 53: ...performing device reboot Remote control via telnet SSH WEB or SNMP applications should be reconfigured to use new IP address 6 18 Ethernet management port net mask address The Ethernet management por...

Page 54: ...P address using the command set_gateway Example Notes New gateway address will take effect only after performing device reboot Remote control via telnet SSH WEB or SNMP applications should be reconfig...

Page 55: ...Example 6 22 System password set_psw To change the M40GBP system password factory default is gtadmin1 Use the command set_psw The new password will take effect after the next login Example 6 23 Unit n...

Page 56: ...nce and in writing by Garland Technology 6 24 Who am I whoami Blink the S OK LED on currently controlled M40GBP unit in order to identify the relevant unit Example 6 25 Display M40GBP versions get_ver...

Page 57: ...to except as authorized in advance and in writing by Garland Technology 6 26 Display M40GBP parameters get_params Show the current M40GBP parameters values Example Ctrl M40GBP get_params Time Tue Jan...

Page 58: ...w the current M40GBP Bypass and operational mode state Note This command resets the Alarm LED Example Fan status displayed if hardware version is 0 1 0 0 or higher Ctrl M40GBP get_dev_state 1 ERROR wr...

Page 59: ...is Garland Technology s property This document may not be copied duplicated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment th...

Page 60: ...luding any part thereof or attachment thereto except as authorized in advance and in writing by Garland Technology 6 28 Display device hardware version get_hw_ver Example 6 29 Display device firmware...

Page 61: ...t thereto except as authorized in advance and in writing by Garland Technology 6 31 Display device health state get_health Fan and temperature status displayed Example For the M40GBP10 Ctrl M40GBP get...

Page 62: ...ves the heartbeat packets fail The link on the monitor ports are ON and the M40GBP does not receive the heartbeat packets unknown The link on the monitor ports are OFF Example 6 33 Display rs232 termi...

Page 63: ...advance and in writing by Garland Technology 6 36 Display device log file get_log The command get_log display the M40GBP log file get_log user ip log_name last_lines_cnt display the full log file or i...

Page 64: ...logy 6 37 Reset log file reset_log The default log file is stored in the internal FLASH memory The log is saved also after reboot or power off The log file is saved in 2 x 4096KB cyclic blocks When tw...

Page 65: ...ault settings are IP address 10 10 10 200 Net mask 255 255 255 0 Gateway 10 10 10 200 hb_interval 5 ms hb_holdtime 20 ms enable snmp traps disabled all snmp trap snmp server ip 192 168 0 6 snmp versio...

Page 66: ...y function or design Confidential This document is Garland Technology s property This document may not be copied duplicated and transferred to electronic or mechanized media or used for any other purp...

Page 67: ...ll use HTTP protocol Example 6 44 Replacing the default certificate for the web UI set_cert For HTTPS connections with the web UI the M40GBP has its certificate By default the M40GBP Factory certifica...

Page 68: ...the M40GBP before the session will be terminated by the M40GBP default 900 sec In case that the WEB session was terminated the Login screen will appear on the WEB browser Example 6 46 Get Set Etherne...

Page 69: ...igured to force the link speed to 1G 10G or auto When it is set to Auto the 10 Bypass segments autodetect the link speed during the bootup of the M40GBP unit In case that no cable is connected to the...

Page 70: ...eartbeat packet length 24 1024 bytes Destination MAC XX XX XX XX XX XX This value will be replaced by the M40GBP to the M40GBP port0 port1 MAC address Source MAC XX XX XX XX XX XX This value will be r...

Page 71: ...lure criteria will be set to unidirectional state and the heartbeat packets are expected to be received by the second monitor port If the second monitor port does not receive the heartbeat packets wit...

Page 72: ...eceive messages from device 6 49 1 Get remote log state The M40GBP remote log state can be retrieved by command get_remote_log_state 6 49 2 Set remote log state The M40GBP remote log state can be set...

Page 73: ...ocol The IBS support multi NTP servers up to 3 NTP can be enabled or disabled default disable 6 50 1 Get NTP state The M40GBP NTP state can be retrieved by command get_ntp_state 6 50 2 Set NTP state T...

Page 74: ...nology 6 50 5 Add NTP server IP Add NTP server IP 6 50 6 Delete NTP server IP 6 50 7 Send NTP request Force NTP request using the command send_ntp_request M40GBP get_ntp_server_ip NTP server ip 192 16...

Page 75: ...echnology 6 51 Timezone 6 51 1 Get timezone list The Command get_timezone_list displays the supported time zones The Time zones are united to groups The Command timezone can retrieve time zone group n...

Page 76: ...aving mode can be disabled or enabled Also can be set timezone GMT X from Etc group M40GBP get_timezone_list Ala Timezone group Africa Dar_es_Salaam GMT 3 Is the above information OK Y n n Timezone gr...

Page 77: ...on needed for the Technical Support team in order to help resolving technical problems M40GBP set_timezone off Mountain Timezone group Canada Mountain GMT 7 Is the above information OK Y n y command s...

Page 78: ...build date Mon Jan 20 13 59 37 2014 swctl build date Mon Jan 20 13 59 43 2014 badas build date Mon Jan 20 13 59 50 2014 snmpd build date Wed Jan 8 14 34 04 2014 support driver build date Sun Jul 28 0...

Page 79: ...e0ed28 0x00e0ed28 0x00e0ed28 0x00e 0ed28 0x00e0ed28 0x00e0ed28 0x00e0ed28 0x00e0ed28 0x00e0ed28 hb_dst_mac_low 0x00230000 0x00250000 0x00270000 0x00290000 0x002b0000 0x002d0000 0x002f 0000 0x00310000...

Page 80: ...c i2c ffe119000 i2c timeout 1000000 us mpc i2c ffe119100 i2c timeout 1000000 us EDAC MC Ver 2 1 0 IPv4 over IPv4 tunneling driver TCP cubic registered Initializing XFRM netlink socket NET Registered p...

Page 81: ...eb_user 6 53 2 Set WEB user name WEB user name can be set by command set_web_user 6 53 3 Set WEB user password WEB user password can be set by command set_web_user_psw 6 54 Multi configuration mechani...

Page 82: ...configuration the M40GBP must be rebooted 6 54 4 Remove saved configuration The command remove_conf is used to remove saved configuration form the Flash memory 6 55 Telnet access The M40GBP support T...

Page 83: ...tOctets RFC 1213 4 RxPktGood snmpEtherStatsRXNoErrors RFC 1757 5 RxUnicastPkts snmpIfInUcastPkts RFC 1213 6 RxMulticastPkts snmpEtherStatsMulticastPkts RFC 1757 7 RxBroadcastPkts snmpEtherStatsBroadca...

Page 84: ...Accounting tac_plus rfc 1 78 txt Inbound PAP Login Password Authentication Protocol TACACS RADUIS disabled by default TACACS RADIUS secret key length can be from 8 to 127 characters Default secret key...

Page 85: ...Garland Technology 6 57 2 Set TACACS RADIUS server IP The M40GBP support multi TCACS servers the command set_tacacs_server_ip sets the main TACACS server 6 57 3 Add TACACS server IP The M40GBPS suppo...

Page 86: ...server IP can be retrieved by command get_tacacs_server_ip 6 57 6 Set RS232 TACACS login By default there is no TACACS server login validate for RS232 access The command set_rs232_tacacs_login enable...

Page 87: ...enables disable the login fallback to the local IBS credentials in case that no TACACS server is available 6 57 9 Get TACACS login fallback TACACS login fallback status can be retrieved by command se...

Page 88: ...57 13 Set RADIUS authentication port RADIUS authentication port can be set by command set_radius_auth_port 1024 49151 6 57 14 Display RADIUS authentication port The state of RADIUS authentication port...

Page 89: ...ed IP range can be added by command set_ mgmt_permit_ip Permitted IP range can be removed by command del_ mgmt_permit_ip Command get parameter NetIp NetMask or all With parameter all command remove al...

Page 90: ...support link drop on network port if correspondent monitor port link gone This Mode can be set independent for each monitor port 6 60 Displaying power supplies states The command get_power_state disp...

Page 91: ...in advance and in writing by Garland Technology 6 60 1 Module power off The command power_off causing the individual M40GBP module to be powered off It enable the user to replace individual M40GBP mod...

Page 92: ...t level of access read only read write trap only read Only with Trap read write with Trap and different SNMP version 1 2c and 3 SHA and AES and SNMP discovery 6 62 1 SNMP_Enrty commands There are 4 di...

Page 93: ...d Technology 6 62 2 add_snmp_entry Add new SNMP entry up to 11 different entries M40GBP add_snmp_entry snmp entry 2 was created New SNMP setting will take effect after apply_snmp command succeeded M40...

Page 94: ...or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Technology 6 62 3 Select SNMP entry sel_snmp_entry In order to...

Page 95: ...SNMP setting will take effect after apply_snmp command succeeded M40GBP apply_snmp SNMP restart is in progress please wait command succeeded M40GBP get_snmp_user snmp user test1 command succeeded M40G...

Page 96: ...eof or attachment thereto except as authorized in advance and in writing by Garland Technology 6 62 5 snmp version set_snmp_ver XXX set snmp version 1 2c 3 default 1 get_snmp_ver M40GBP get_snmp_ver s...

Page 97: ...can be assigned to one of the 11 SNMP entries There are 4 different commands to control the SNMP servers IP get_snmp_srv_ip show the SNMP servers IP for the current selected entry add_snmp_srv_ip add...

Page 98: ...lectronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Technology 6 62 8 add_snmp_srv_ip...

Page 99: ...Garland Technology 6 62 9 del_snmp_srv_ip Note The main SNMP srv_ip cannot be deleted M40GBP get_snmp_entry entry index 1 snmp user customer snmp version 1 snmp community status on snmp community acce...

Page 100: ...modify the IP address of the main SNMP server set_snmp_srv_ip xxx xxx xxx xxx set MAIN snmp server ip address default 192 168 0 6 M40GBP sel_snmp_entry 2 command succeeded M40GBP get_snmp_entry entry...

Page 101: ...get set_snmp_access Each entry support different level of access read only read write trap only read only with Trap set_snmp_access access set snmp community access read read_write trap read_trap read...

Page 102: ...set_snmp_user_psw The SNMP V 3 requires to set password to encrypt decrypt the SNMP information set_snmp_user_psw set_snmp_user_psw OLD NEW set snmp user password 8 60 symbols 6 62 13 snmp community s...

Page 103: ...snmp trap port min 1 max 49151 default 162 get_snmp_trap_port 6 62 15 SNMP MSG IP port get set_snmp_msg_port Control the SNMP msg IP port set_snmp_msg_port XXX set snmp msg port min 1 max 49151 defau...

Page 104: ...PApplState 1 12 INTEGER read only unknown 1 fail 2 alive 3 Application state M40GBPTermStatus 1 13 INTEGER read only disconnected 1 connected 2 Rs232 management port status M40GBPLogLastLine 1 14 INTE...

Page 105: ...read write update 1 force 2 Update the M40GBP firmware M40GBP SysUpdateStatus 3 13 OCTET STRING SIZE 1 1024 read only Get M40GBP firmware update status M40GBP SysResetErr 3 14 INTEGER read write rese...

Page 106: ...read write Remove one or all management port permitted network IP String consists of IP address and netmask address separated by semicolon 192 168 0 0 24 193 151 0 0 22 all_permitted_ip M40GBPSysGetM...

Page 107: ...R read write auto 1 10g 2 1g 3 Get set dual rate segment speed M40GBPConf2pl 4 1 INTEGER read write enable 1 disable 2 Get Set two port link mode M40GBPConfHbExpState 4 2 INTEGER read write bypass 2 t...

Page 108: ...yDefault 6 1 INTEGER write Restore system default parameter M40GBPTrapConfApplFail 7 2 INTEGER read write enable 1 disable 2 Enable Disable getting trap info on application failed restored events stat...

Page 109: ...parameters set_trap trap trap new_state new_state on off trap o appl application state change trap o bp bypass state change trap o mon monitor ports state change trap o net network ports state change...

Page 110: ...t may not be copied duplicated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in w...

Page 111: ...is restored M40GBPTrapNet1LinkDown 14 Trap is sent when network port 1 link drops M40GBPTrapNet1LinkUp 15 Trap is sent when network port 1 link is restored M40GBPTrapTermDisc 16 Trap is sent when loca...

Page 112: ...eof or attachment thereto except as authorized in advance and in writing by Garland Technology ibsTrapNet1Enable2pl 36 This trap is sent when network port 1 was enable by 2pl function ibsTrapNet0Disab...

Page 113: ...20000 M40GBP MIB M40GBP TrapConfTerm 0 SNMP v2c set request snmpset v 2c c customer 10 10 10 20000 M40GBP MIB M40GBP TrapConfTerm 0 on SNMP v3 get request snmpget v 3 u customer l authPriv a SHA A gta...

Page 114: ...ied duplicated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garlan...

Page 115: ...device_ip_address index html en Where device_ip_address M40GBP Ethernet Management port IP address Note If the WEB interface is inactive more than the web_expired_time a login screen will be prompt Mo...

Page 116: ...chment thereto except as authorized in advance and in writing by Garland Technology 7 4 Information page 7 4 1 Logoff The M40GBP will terminate the WEB session in case that the WEB session is passive...

Page 117: ...y information 7 4 3 1 Device info area description The Device info area contains common information Device hardware version Device firmware version Device software version Device U boot version Device...

Page 118: ...document may not be copied duplicated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance...

Page 119: ...is ON the M40GBP send heartbeat packets on its monitor ports If the M40GBP does not detect the heartbeat packet received from the monitor ports the M40GBP will switch to Active Bypass or TAP TAPI12 T...

Page 120: ...rop mode 7 6 1 5 HB active expire select box When heartbeat active mode is ON the M40GBP send heartbeat packets on its monitor ports If the M40GBP does not detect the heartbeat packet received from th...

Page 121: ...restore to its default state when both monitor ports receives the heartbeat packets 7 6 2 4 M2N M2N monitor port to network port link fail mode support link drop on network port if correspondent moni...

Page 122: ...mprove reliability function or design Confidential This document is Garland Technology s property This document may not be copied duplicated and transferred to electronic or mechanized media or used f...

Page 123: ...This document is Garland Technology s property This document may not be copied duplicated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or...

Page 124: ...urpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Technology 7 7 1 2 Selective bypass mode control Set the selective bypass up down mode...

Page 125: ...d transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Technology 7 8...

Page 126: ...saves these different configurations on internal flash memory 1 MB 7 8 2 TACACS RADIUS configuration area The M40GBP support TACACS and RADIUS for remote access WEB access SNMP access SSH access Telne...

Page 127: ...by Garland Technology 7 8 3 Time configuration area 7 8 3 1 Time state Time format mm DD HH MM YYYY Where mm month DD day HH hour MM minute YYYY year 7 8 3 2 Daylight state Set the Daylight saving ti...

Page 128: ...IP address will take affect only after device reboot Remote control via telnet SSH WEB or SNMP applications should be reconfigured to use new NETMASK IP address 7 8 5 3 Default gateway The default gat...

Page 129: ...onfidential This document is Garland Technology s property This document may not be copied duplicated and transferred to electronic or mechanized media or used for any other purpose including any part...

Page 130: ...d and the confirm new password are required in order to set the Password for the selected interface on the Interface dropdown menu 7 10 4 Session timeout The web_exp_time command sets the time that th...

Page 131: ...and in writing by Garland Technology 7 11 SNMP page 7 11 1 SNMP Entry The M40GBP supports up to 11 different SNMP entries Entry user name community Each entry support up to 8 different SNMP servers E...

Page 132: ...in 1 max 49151 default 161 Trap port min 1 max 49151 default 162 7 11 8 SNMP trap account 7 11 9 SNMP trap account allow to add remove view additional destinations for SNMP traps SNMP trap control SNM...

Page 133: ...land Technology s property This document may not be copied duplicated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto e...

Page 134: ...licated and transferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Techn...

Page 135: ...sferred to electronic or mechanized media or used for any other purpose including any part thereof or attachment thereto except as authorized in advance and in writing by Garland Technology 7 12 2 Rem...

Page 136: ...function or design Confidential This document is Garland Technology s property This document may not be copied duplicated and transferred to electronic or mechanized media or used for any other purpos...

Page 137: ...s or data herein to improve reliability function or design Confidential This document is Garland Technology s property This document may not be copied duplicated and transferred to electronic or mecha...

Page 138: ...may not function properly We recommend the process be done in an environment with a steady power supply preferably with UPS 7 14 2 System restore are 7 14 2 1 Set default parameters Restore the facto...

Page 139: ...rd Watch Dog Timer WDT Controllers Software programmable time out interval Software Programmable WDT Enable Disable Independent Bypass Normal Tap Linkdrop operation in every module Supports up to thre...

Page 140: ...y products or data herein to improve reliability function or design Confidential This document is Garland Technology s property This document may not be copied duplicated and transferred to electronic...

Page 141: ...n advance and in writing by Garland Technology 8 1 Bypass Specifications WDT Interval Software Programmable Routing Transmit heart beat packet every 3mS 10Sec Default 5mS Verification packets received...

Page 142: ...ept as authorized in advance and in writing by Garland Technology 9 Technical Specifications 9 1 M40GBP1U 9 1 1 M40GBP1U Bypass Switch 1U Host System Technical Specifications Dockings Front holders Vo...

Page 143: ...and off if there is a failer in power supply module or when extracting the power supply module from the system System Status LEDs 3 LEDs 4 Sys OK System Normal Operation Light Green Who I m in rack i...

Page 144: ...y function or design Confidential This document is Garland Technology s property This document may not be copied duplicated and transferred to electronic or mechanized media or used for any other purp...

Page 145: ...andard Network topology Fiber Gigabit Ethernet 40GBase SR4 850nM Data Transfer Rate 40G per port Cables and Operating distance Multimode fiber 50um 50m maximum on OM3 MMF 75m maximum on OM4 MMF Theore...

Page 146: ...sfer Rate 40Gbit s per port Network ports Cables and Operating distance Single mode fiber 5000m maximum at 9 um Theoretical Distance Defined as half a distance Insertion Loss Passive Normal Mode Typic...

Page 147: ...r 10G 1G Ethernet Technical Specifications 10GBase SR 1000Base SX Adapters IEEE Standard Network topology 1000Base SX 10GBase SR 850nM Data Transfer Rate 20Gbit s in full duplex mode per port Cables a...

Page 148: ...fer Rate 20Gbit s in full duplex mode per port Network ports Cables and Operating distance Single mode fiber 5000m maximum at 9 um Insertion Loss Passive Normal Mode Typical 1 2 dB Maximum 1 6dB Inser...

Page 149: ...The fiber optic ports contain a Class 1 laser device When the ports are disconnected always cover them with the provided plug If an abnormal fault occurs skin or eye damage may result if in close pro...

Page 150: ...Use any TFTP server utility to create TFTP server for example tftpd32 which is a free utility 1 Create tftp directory 2 Create tftp tftpboot directory The working directory for the TFTP software shou...

Page 151: ...ove copyright notice appears in all copies and that both that copyright notice and this permission notice appear in supporting documentation and that the name of CMU and The Regents of the University...

Page 152: ...D ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUC...

Page 153: ...ice this list of conditions and the following disclaimer in the documentation and or other materials provided with the distribution Neither the name of the Sun Microsystems Inc nor the names of its co...

Page 154: ...ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Part 6 Cisco BUPTNIC copyright notice BSD Copyright c 2004 Cisco Inc and Information Network Center of Beijin...

Page 155: ...roducts derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO...

Page 156: ...THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE...

Page 157: ...dgement This product includes software developed by the NetBSD Foundation Inc and its contributors 4 Neither the name of The NetBSD Foundation nor the names of its contributors may be used to endorse...

Page 158: ...fy and distribute this software for any purpose and without fee is hereby granted provided that this copyright and permission notice appear on all copies and supporting documentation the name of Lars...

Page 159: ...WORK INC DO NOT WARRANT THAT THE FUNCTIONS CONTAINED IN THE SOFTWARE WILL MEET LICENSEE S REQUIREMENTS OR THAT OPERATION WILL BE UNINTERRUPTED OR ERROR FREE The Regents of the University of Michigan a...

Reviews: