Take effect after setting
M40GBPSnmpApply
M40GBP SnmpPassword
2.4
OCTET STRING
(SIZE(17..121))
write-only
Define the SNMP v3 and WEB interface
password.
Parameter consists of old and new
passwords separated by semicolon.
Take effect after setting
M40GBPSnmpApply
M40GBP SnmpApply
2.5
INTEGER
write-only
apply (1)
Activate all the SNMP changes.
M40GBP SysTime
3.1
OCTET STRING
(SIZE(1..32))
read-write
Set/Get device current time/Date
M40GBP SysIp
3.3
IpAddress
read-write
M40GBP SysNetmask
3.4
IpAddress
read-write
Set/Get M40GBP IP subnet mask.
M40GBP SysGateway
3.5
IpAddress
read-write
Set/Get M40GBP gateway IP address.
M40GBP SysResetLog
3.6
INTEGER
write-only
reset
M40GBP SysReboot
3.8
INTEGER
write-only
reboot (1)
M40GBP UnitName
3.9
OCTET STRING
(SIZE(1..32))
read-write
M40GBP SysTftpIp
3.10
IpAddress
read-write
Set/Get TFTP server IP address.
M40GBP SysTftpRoot
3.11
OCTET STRING
(SIZE(1..64))
read-write
Set/Get TFTP server root directory.
M40GBP SysUpdate
3.12
INTEGER
read-write
update(1),
force(2)
.
M40GBP SysUpdateStatus
3.13
OCTET STRING
(SIZE(1..1024))
read-only
Get M40GBP firmware update status.
M40GBP SysResetErr
3.14
INTEGER
read-write
reset(1)
M40GBPSysWhoami
3.15
INTEGER
read-write
on(1),
off(2)
Unit identification.
On/off system OK led blink.
M40GBPSysRemoteLog
3.16
INTEGER
read-write
on(1),
off(2)
Get/set remote log state.
NOTE: next SNMP command should be
send not before 1 sec after this
command
M40GBPSysRAemoteLogIp
3.17
IpAddress
read-write
Set/Get remote log server IP address.
NOTE: next SNMP command should be
send not before 1 sec after this
command
M40GBPSysNTP
3.18
INTEGER
read-write
on(1),
off(2)
Get/set NTP state.
M40GBPSysNTPServerIp
3.19
IpAddress
read-write
Set/Get NTP server IP address.
M40GBPSysDayLight
3.20
INTEGER
read-write
default(1),
off(2)
Get/set daylight saving mode.
The daylight saving mode will be set
finally by M40GBPSysTimezone.
M40GBPSysTimezone
3.21
OCTET STRING
(SIZE(1..64))
read-write
Get/set device timezone.
Timezone examples: America/Barbados,
Asia/Bangkok.
Full list of supported names can be
found in Linux.
Command sets the default daylight
saving mode.
To disable default daylight saving mode
perform
M40GBPSysDayLight with parameter OFF first. To complete timezone setting reboot should be issued.
M40GBPSysWebUser
3.22
OCTET STRING
(SIZE(5..30))
read-write
Get/set the WEB user name.
M40GBPSysWebPassword
3.23
OCTET STRING
(SIZE(17..121))
read-write
Set the WEB user password.Set only
variable, read will return zero length
string. Parameter consists of old and
new passwords separated by semicolon.
M40GBPSysSaveConfig
3.24
OCTET STRING
(SIZE(4..20))
read-write
Save device configuration. Set only
variable, read will return zero.
M40GBPSysRestoreConfig
3.25
OCTET STRING
(SIZE(4..20))
read-write
Restore device configuration. Set only
variable, read will return zero. The unit
will be rebooted.