6.19 Ethernet management port gateway IP address
The Ethernet management port default gateway IP address is 10.10.10.200.
The net default gateway IP address can be set to different IP address using the command: set_gateway
Example:
Notes:
New gateway address will take effect only after performing device reboot.
Remote control via telnet, SSH, WEB or SNMP applications should be reconfigured to
use new gateway address.
6.20 Time
To change the M40GBP date and time use the command “set_time mm DD HH MM YYYY”
Where:
mm - month,
DD - day,
HH - hour ( 24 hours format),
MM - minute,
YYYY -year
Example:
M40GBP$ get_gateway
default gateway ip address: 10.10.10.200
command succeeded.
M40GBP$ set_gateway 10.10.10.200
New default gateway will take effect after reboot.
command succeeded.
M40GBP$ get_gateway
default gateway ip address: 10.10.10.200
command succeeded.
M40GBP$
M40GBP$get_time
Time: Thu Feb 5 13:10:00 2009
command succeeded.
M40GBP$set_time 2 5 13 10 2010
Thu Feb 5 13:10:34 2009 0.000000 seconds
Fri Feb 5 13:10:00 2010 0.000000 seconds
command succeeded.
M40GBP$get_time
Time: Fri Feb 5 13:10:02 2010
command succeeded.
M40GBP$