13–10–612 Page 53
SYMPTOM
POSSIBLE CAUSE
REMEDY
Oil Carry–Over
1.
Overfilling the reservoir.
1.
Drain excess oil
from system.
Air/oil under pressure will cause severe personal injury or death. Shut down com-
pressor, relieve system of all pressure, disconnect, tag and lockout power supply
to the starter before removing valves, caps, plugs, fittings, bolts, and filters.
2.
Clogged, broken or loose
2.
Tighten or replace
oil return lines
faulty lines.
3.
Ruptured oil separator
3.
Replace element.
element.
4.
Loose assembly.
4.
Tighten all fittings
and gaskets.
5.
Foam caused by use of
5.
Use Gardner Denver
incorrect oil.
AEON 4000 or 9000 SP
Lubricating Coolant.
6.
Inoperative minimum
6.
Clean out or replace
pressure valve causing low
valve.
operating pressure.
7.
Operation at elevated
7.
Reduce temperature. See
discharge temperatures.
High Discharge Air
Temperature, page 2,
this section.
8.
Scavenge line check
8.
Replace check valve.
valve failure.
Oil Carry–Over (Continued)
9.
Water condensate in oil.
9.
Check oil reservoir
temperature and if low,
change thermal mixing
valve element to a
higher temperature.
Summary of Contents for ELECTRA-SAVER EAU PD - 200 HP
Page 13: ...13 10 612 Page 3 FIGURE 1 4 STARTER BOX FIGURE 1 5 PACKAGE CONTROLLER AND STARTERS...
Page 16: ...13 10 612 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Page 17: ...13 10 612 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Page 40: ...13 10 612 Page 30 FIGURE 4 8 CONTROL SCHEMATIC COMPRESSOR AT FULL LOAD 214ECM797 Ref Drawing...
Page 42: ...13 10 612 Page 32 FIGURE 4 10 WIRING DIAGRAM 212EAP546 Ref Drawing...
Page 43: ...13 10 612 Page 33 FIGURE 4 11 AUTO SENTRY ES CONTROLLER DISPLAY...
Page 45: ...13 10 612 Page 35 FIGURE 5 1 FLOW DIAGRAM AIR OIL SYSTEM 215EAU797 Ref Drawing...
Page 65: ......