13–10–612 Page 48
When assembling the element in the body, be sure the
wing nut is tight and the clamp on the filter holds the
cover firmly against the gasket.
Do not oil this element. Do not wash
in inflammable cleaning fluids. Do
not use solvents other than water. Im-
proper cleaning may damage the ele-
ment.
Never operate the unit without the ele-
ment. Never use elements that are
damaged, ruptured or wet. Never use
gaskets that won’t seal. Keep spare
elements and gaskets on hand to re-
duce downtime. Store elements in a
protected area free from damage, dirt
and moisture. Handle all parts with
care.
Use only genuine Gardner Denver air
filter elements on Gardner Denver
compressor units. Genuine parts are
available through your authorized
Gardner Denver distributor.
Filter Element Life – The element should be replaced
after six cleanings or if:
1.
Visual inspection indicated a rupture, crack, or pin
hole in the pleated media. Inspection should be
done by placing a bright light inside the element.
2.
Pressure drop through a filter with a freshly
cleaned element is below 3 inches of water with
compressor running at full load – this would indi-
cate a rupture or crack.
Inlet Screen and Tube – Inspect the inlet screen and
tube for dirt accumulation each time the filter element
is serviced. Clean the tube when required by ramming
a clean dry cloth through the tube. Wipe the inside of
the filter body to remove any dirt falling from the inlet
tube before reinstalling the element.
Causes of short element life include: severe dust
conditions, infrequent servicing, improper cleaning, or
contamination by oil or chemical fumes.
Summary of Contents for ELECTRA-SAVER EAU PD - 200 HP
Page 13: ...13 10 612 Page 3 FIGURE 1 4 STARTER BOX FIGURE 1 5 PACKAGE CONTROLLER AND STARTERS...
Page 16: ...13 10 612 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Page 17: ...13 10 612 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Page 40: ...13 10 612 Page 30 FIGURE 4 8 CONTROL SCHEMATIC COMPRESSOR AT FULL LOAD 214ECM797 Ref Drawing...
Page 42: ...13 10 612 Page 32 FIGURE 4 10 WIRING DIAGRAM 212EAP546 Ref Drawing...
Page 43: ...13 10 612 Page 33 FIGURE 4 11 AUTO SENTRY ES CONTROLLER DISPLAY...
Page 45: ...13 10 612 Page 35 FIGURE 5 1 FLOW DIAGRAM AIR OIL SYSTEM 215EAU797 Ref Drawing...
Page 65: ......