13–10–612 Page 45
SECTION 6
AIR FILTERS
AIR FILTER – The air filter furnished as standard
equipment is a panel type washable filter. The filter
must receive proper maintenance if maximum service
is to be obtained from the unit. Establishing adequate
and timely filter service is MOST IMPORTANT. With
wide variation of dust conditions encountered, only ex-
perience can determine the proper time element for
servicing filters. Although a paper filter element is nor-
mally considered expendable, proper and careful
cleaning can extend its original life several times.
Filter Element – Service the air filter element when the
”CHANGE AIR FILTER” LED is illuminated. Clean ev-
ery 50 to 250 operating hours depending on dust condi-
tions. Inspect every few days until experience deter-
mines the proper time for servicing. Higher than normal
current use by the motor or loss of compressor delivery
may indicate a need for servicing the filter element.
Use only genuine Gardner Denver air
filter elements on Gardner Denver
compressor units. Genuine parts are
available through your authorized
Gardner Denver distributor.
To Service:
Remove louvered filter cover and filter element by re-
moving the six (6) cover to enclosure screws.
Two methods of cleaning are recommended. Use of
compressed air is effective when the major contami-
nant is dust. Washing is effective on carbon, soot, and
oil laden elements.
DO NOT ATTEMPT TO CLEAN ELEMENTS BY
BEATING OR RAPPING.
When air is used, direct a jet of air (100 PSI maximum)
against the clean air side of the element in the opposite
direction of normal air flow. Move the air jet up and
down the pleat, slowly moving across the face of the
element. Nozzle must be kept at least one inch away
from the element. Take care the paper is not ruptured
by the nozzle or air jet.
When cleaning by washing, use a good non–sudsing
detergent and water. Soak the element in a solution of
two (2) ounces of detergent per gallon of water (140
_
F. maximum) for at least 15 minutes. Swish the element
around in the solution (2 minutes) to help remove dirt.
Warm solution gives best results. Rinse the element
with a stream of water (40 PSI maximum) opposite to
normal air flow until rinse water is clear. DRY THE ELE-
MENT THOROUGHLY BEFORE USING. DO NOT
USE LIGHT BULBS FOR DRYING. Warm air (160
_
F.
or less) must be circulated as high surface tempera-
tures can burn or scorch the filter paper.
After cleaning, thoroughly inspect the element for dirt
on the clean air side, holes or damage, by looking
through the element toward a bright light. Do not reuse
damaged elements.
Do not oil this element. Do not wash
in inflammable cleaning fluids. Do
not use solvents other than water. Im-
proper cleaning may damage the ele-
ment.
Never operate the unit without the ele-
ment. Never use elements that are
damaged, ruptured or wet. Never use
gaskets that won’t seal. Keep spare
elements and gaskets on hand to re-
duce downtime. Store elements in a
protected area free from damage, dirt
and moisture. Handle all parts with
care.
Filter Element Life – The element should be replaced
after six (6) cleanings or if:
1.
Visual inspection indicates a rupture, crack or pin
hole in the pleated media. Inspection should be
done by placing a bright light inside the element.
2.
Pressure drop through a filter with a freshly
cleaned element is below 3 inches of water with
compressor running at full load – this would indi-
cate a rupture or crack.
Summary of Contents for ELECTRA-SAVER EAU PD - 200 HP
Page 13: ...13 10 612 Page 3 FIGURE 1 4 STARTER BOX FIGURE 1 5 PACKAGE CONTROLLER AND STARTERS...
Page 16: ...13 10 612 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Page 17: ...13 10 612 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Page 40: ...13 10 612 Page 30 FIGURE 4 8 CONTROL SCHEMATIC COMPRESSOR AT FULL LOAD 214ECM797 Ref Drawing...
Page 42: ...13 10 612 Page 32 FIGURE 4 10 WIRING DIAGRAM 212EAP546 Ref Drawing...
Page 43: ...13 10 612 Page 33 FIGURE 4 11 AUTO SENTRY ES CONTROLLER DISPLAY...
Page 45: ...13 10 612 Page 35 FIGURE 5 1 FLOW DIAGRAM AIR OIL SYSTEM 215EAU797 Ref Drawing...
Page 65: ......