13–10–612 Page 54
AUTO SENTRY ES CONTROLLER
TROUBLE SHOOTING GUIDE
ADVISORIES
READING
ACTION
”CHANGE SEPARATOR” Light
Separator differential is greater than 8 psid
(Flashing or on steadily)
Change separator.
On Startup
CHANGE AIR FILTER
Inspect/Replace –– air filter if needed. See Section 6.
LOW AMBIENT
The advisory comes on –– if the receiver or air end discharge
is less than 40
_
F (4.4
_
C). Refer to corrective measures for
low ambient conditions in the Operator’s Manual.
See Section 2, Page 2.
HIGH TEMPERATURE
The advisory comes on –– when the temperature exceeds
210
_
F (99
_
C.)
Probable cause –– plugged or dirty cooler, high ambient
conditions, or blown fuses on fan motor.
Gardner Denver factory remanufactured replacement compressor air end units are
available from your authorized distributor, on an exchange basis, for all rotary
screw compressor units.