background image

PT Range Operators Handbook
PT models

Covering Models:-

BAMBI AIR COMPRESSORS LTD

152 Thimble Mill Lane

Heartlands

Birmingham

B7 5HT

Tel:  0121 322 2299

Fax: 0121 322 2297

Email: [email protected]

www.bambi-air.co.uk

PT5  /  PT8  /  PT15  /  PT24  /  PT50D

Summary of Contents for PT15

Page 1: ... Handbook PT models Covering Models BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT Tel 0121 322 2299 Fax 0121 322 2297 Email sales bambi air co uk www bambi air co uk PT5 PT8 PT15 PT24 PT50D ...

Page 2: ...n the company Provided the operating instructions have been followed and the compressor has been properly maintained Bambi PT compressors are guaranteed against faulty workmanship for a period of 1 year The air receiver is guaranteed for 5 years The guarantee does not cover damage by misuse incorrect parts or service Contact Bambi Air Compressors or your retailer for further information Technical ...

Page 3: ...ite the compressor level in both planes Allow access for maintenance all around the compressor Site in a dry area avoiding damp or humid conditions The site must be dust free well ventilated and have a cool ambient temperature 0 to 40 C should be regarded as the minimum and maximum allowable ambient What you must not do Enclose the compressor or allow hot air generated by the motor to re circulate...

Page 4: ...ing the unloader valve discharging the residual delivery pipe pressure This is normal Adjusting Outlet Pressure Use the pressure regulator to adjust the outlet pressure To increase line pressure rotate the knob in a clockwise direction to decrease turn anti clockwise It is possible to lock the setting by pushing the knob down until it clicks home There are two pressure gauges on each model The lar...

Page 5: ...ce Technical We recommend the compressor has a maximum 65 duty cycle to prolong pump life Note The motor must never be allowed to run continuously otherwise it will overheat and may become damaged The duty cycle is calculated over 10 minutes meaning that if the motor runs continuously for 6 5 minutes it must then rest for 3 5 minutes Do not ignore air leaks All air connections must be leak free to...

Page 6: ...er BPB1078 11 On off tap BPB1079 12 Regulator BPB1080 13 40mm line pressure gauge BPB1077 14 Elbow M F BPB1139 15 Extension BPB0150 16 Connector BPB0810 17 50mm tank pressure gauge BPB1081 18 Delivery pipe BPB1258 19 Connector BPB1242 20 Tee piece MMM BPB1239 21 Non return valve BPB1086 22 Elbow for air pipe BPB0043 23 Air pipe BPB0203 24 Inserts BPB0078 25 Capacitor box BPB1236 26 Capacitor BPB12...

Page 7: ...or BPB1080 13 40mm line pressure gauge BPB1077 14 Elbow M F BPB1139 15 Tee piece MFF BPB1109 16 Connector BPB0810 17 50mm tank pressure gauge BPB1081 18 Delivery pipe BPB1258 19 Connector BPB1242 20 Tee piece MMM BPB1239 21 Non return valve BPB1086 22 Elbow for air pipe BPB0043 23 Air pipe BPB0203 24 Elbow BPB1257 25 Inspection plug BPB0255 26 Inspection plug seal BPB0502 27 Siphon tube BPB0028 28...

Page 8: ... BPB0066 7 Drain pipe BPB0414 8 Pressure relief valve BPB1084 9 Pressure switch BPB1074 10 Adapter BPB1078 11 On off tap BPB1079 12 Regulator BPB1080 13 40mm line pressure gauge BPB1077 14 Elbow M F BPB1139 15 Elbow BPB1257 16 Connector BPB0810 17 50mm tank pressure gauge BPB1081 18 Delivery pipe BPB1258 19 Connector BPB1242 20 Tee piece MMM BPB1239 21 Non return valve BPB1086 22 Elbow for air pip...

Page 9: ...BPB1074 10 Adapter BPB1078 11 On off tap BPB1079 12 Regulator BPB1080 13 40mm line pressure gauge BPB1077 14 Siphon tube BPB0028 15 Connector BPB0152 16 50mm tank pressure gauge BPB1081 17 Delivery pipe BPB1258 18 Connector BPB1242 19 Tee piece MMM BPB1239 20 Non return valve BPB1086 21 Elbow for air pipe BPB0043 22 Air pipe BPB0203 23 Elbow BPB1257 24 Capacitor box BPB1236 25 Capacitor BPB1260 3 ...

Page 10: ...Part no 1 Cylinder head seal BPB1250 2 Valve plate assembly BPB1251 3 Cylinder BPB1253 4 Connecting rod BPB1254 5 Top washer BPB1254 6 Piston ring BPB1254 7 Airway tube inc O ring seal BPB1252 8 Motor fan LH BPB1255 9 Motor fan RH BPB1264 10 Fan cover BPB1256 ...

Page 11: ... Date installed____________________________ Date Maintenance work Signature Company BPPT 1 Service Kit covers all models PT50D requires two kits SERVICE KITS BPB0655 required to change the Coalescing Filter Element 9 ...

Page 12: ...uropea listada abajo Bambi Air Compressors verklaart dat dit product voldoet aan de onderstaande Europese Richtlijnen Bambi Air Compressors erklart hiermit dass dieses Produkt mit den Bestimmungen der Nachstehenden EU Richtlinien ubereinstimmt Machinery Safety Standard 2006 42 EC Machinery Directive 2014 68 EU Electromagnetic Compatibility 2014 30 EU Simple Pressure Vessels 2014 29 EU 105 EC EN600...

Reviews: