background image

 

ULTRA QUIET & OIL FREE 

 

AIR COMPRESSOR 

 

OWNER'S MANUAL 

 

 

CALIFORNIA AIR TOOLS 

 

20060DCC 

 

6.0 HP 

20 GALLON 

220 VOLTS  60 HERTZ 

ULTRA-QUIET AIR COMPRESSOR 

98% DRY AIR SYSTEM 

WWW.CALIFORNIAAIRTOOLS.COM                           Customer Support   1-866-409-4581     

Summary of Contents for 20060DCC

Page 1: ...T OIL FREE AIR COMPRESSOR OWNER S MANUAL CALIFORNIA AIR TOOLS 20060DCC 6 0 HP 20 GALLON 220 VOLTS 60 HERTZ ULTRA QUIET AIR COMPRESSOR 98 DRY AIR SYSTEM WWW CALIFORNIAAIRTOOLS COM Customer Support 1 86...

Page 2: ...______________10 MAINTENANCE _________________________________11 Draining the Air Tank ___________________________11 Changing the Air Filter__________________________11 Testing for Leaks _____________...

Page 3: ...grounding plug is able to result in a risk of electric shock When repair or replacement of the in a risk of electric shock When repair or replacement of the cord or plug is required do not connect th...

Page 4: ...the air compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are c...

Page 5: ...hments Never make adjustments to the factory set pressures Never exceed manufacturer s maximum allowable pressure rating attachments Because of extreme heat do not use plastic pipe or lead tin solder...

Page 6: ...e important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed please contact...

Page 7: ...7 Customer Support 1 866 409 4581 AIR COMPRESSOR...

Page 8: ...wn into the air compressor is clean The air compressor should not be used in areas where dust or particulates are in the air This will damage the motor and impair proper operation IMPORTANT Always use...

Page 9: ...compressor or cords if hands or feet are DO NOT touch air compressor or cords if hands or feet are wet wet Ensure that all cords are free of damage before connecting Ensure that all cords are free of...

Page 10: ...NOT touch hot surfaces because they can cause severe burns Do not touch the air compressor s cylinder head During operation the cooling fins of the cylinder head and delivery pipe become hot Allow the...

Page 11: ...ht Do not overtighten A small leak in any hose or pipe connection will reduce the air compressor s performance To test for small leaks spray a small amount of soapy water on the area suspected of leak...

Page 12: ...e burned out Contact Customer Support The motor does not start and makes a humming noise Capacitor is burned out Replace capacitor The motor does not start or starts slowly Low voltage supply to the m...

Page 13: ...rth wire Green Red cords for Capacitor Electric cord for motor Solenoid valve Electric cord for motor Pressure switch Overload protector MAX temperature 135 C Pressure switch Safety valve Pressure gau...

Page 14: ...warranty gives you specific legal rights and you may also have other rights which may vary from state to state Disclaimer of Other Warranties To the fullest extent permitted by applicable law this lim...

Page 15: ...install the air compressor 11 Acts of God The application of these exclusions will be determined at the sole discretion of California Air Tools Inc Registration Warranty registration with California A...