manualshive.com logo in svg
background image

This manual contains important safety information and must be made
available to all personnel who operate and/or maintain this product.
Carefully read this manual before attempting to operate or perform
maintenance on this compressor.

Fill Out & Return Warranty Registration Card Located Inside

Manual No. 50314-200

October 2008 Edition

Q T

Q T

Q T

Q T

Q T

®

®

®

®

®

 Industrial & Air Master Series

 Industrial & Air Master Series

 Industrial & Air Master Series

 Industrial & Air Master Series

 Industrial & Air Master Series

Model QT

Model QT

Model QT

Model QT

Model QT-10

-10

-10

-10

-10

Parts Manual

Record of Change 200

Manual Brought to You By: IndustrialAirPower.com

Содержание Quincy Air Master QT-10

Страница 1: ...his compressor Fill Out Return Warranty Registration Card Located Inside Manual No 50314 200 October 2008 Edition Q T Q T Q T Q T Q T Industrial Air Master Series Industrial Air Master Series Industrial Air Master Series Industrial Air Master Series Industrial Air Master Series Model QT Model QT Model QT Model QT Model QT 10 10 10 10 10 Parts Manual Record of Change 200 Manual Brought to You By In...

Страница 2: ...tion Valve Unloader Assemblies 11 Decals 11 Gasket Set 12 Recommended Spare Parts 12 Overhaul Kits 12 Head Kits 12 Typical Unit Repair Parts List 13 14 INTRODUCTION ThismanualprovidesinformationfortheModel QT 10 reciprocating compressor per Record of Change 200 The Model QT 10 is an aircooled two stage two cylinder splash lubricated compressor with up to 175 PSI continuous pressure capability It h...

Страница 3: ...UIN CIP LUBRICANT Refer to the chart below to order Quin Cip compres sor oil from your local authorized Quincy distributor CRANKCASE LUBRICANT CAPACITY Model Capacity QT 10 2 5 qts 2 37 litres SERIAL NUMBER IDENTIFICATION The unitserialnumberidentificationtagislocatedon the air tank top plate The basic compressor serial number decal is located on the side of the crankcase opposite the oil fill sid...

Страница 4: ...ustrial Air Master Quincy Compressor 50314 200 October 2008 3 3501 Wismann Lane Quincy IL 62305 3116 CRANKSHAFTGROUP116174 CRANKSHAFTGROUP116174 CRANKSHAFTGROUP116174 CRANKSHAFTGROUP116174 CRANKSHAFTGROUP116174 ...

Страница 5: ...Industrial Air Master Quincy Compressor 50314 200 October 2008 4 3501 Wismann Lane Quincy IL 62305 3116 CRANKCASEGROUP116175 CRANKCASEGROUP116175 CRANKCASEGROUP116175 CRANKCASEGROUP116175 CRANKCASEGROUP116175 ...

Страница 6: ...y Compressor 50314 200 October 2008 5 3501 Wismann Lane Quincy IL 62305 3116 CYLINDER HEAD GROUP 116178 CYLINDER HEAD GROUP 116178 CYLINDER HEAD GROUP 116178 CYLINDER HEAD GROUP 116178 CYLINDER HEAD GROUP 116178 without head unloaders ...

Страница 7: ...ssor 50314 200 October 2008 6 3501 Wismann Lane Quincy IL 62305 3116 CYLINDER HEAD GROUP 116178 001 CYLINDER HEAD GROUP 116178 001 CYLINDER HEAD GROUP 116178 001 CYLINDER HEAD GROUP 116178 001 CYLINDER HEAD GROUP 116178 001 with head unloaders ...

Страница 8: ...4 200 October 2008 7 3501 Wismann Lane Quincy IL 62305 3116 CONNECTING ROD PISTON GROUP 116176X CONNECTING ROD PISTON GROUP 116176X CONNECTING ROD PISTON GROUP 116176X CONNECTING ROD PISTON GROUP 116176X CONNECTING ROD PISTON GROUP 116176X low pressure ...

Страница 9: ... 200 October 2008 8 3501 Wismann Lane Quincy IL 62305 3116 CONNECTING ROD PISTON GROUP 116177X CONNECTING ROD PISTON GROUP 116177X CONNECTING ROD PISTON GROUP 116177X CONNECTING ROD PISTON GROUP 116177X CONNECTING ROD PISTON GROUP 116177X high pressure ...

Страница 10: ...ine pressure gauge relief valve check valve discharge line to low and high pressure head unloaders pilot valve Pilot valve is open stem screwed out for Continuous Run operation Pilot valve is closed stem screwed in Control Piping For Automatic Start Stop with loadless starting Control Piping For Continuous Run Control Piping For Dual Control to low and high pressure head unloaders CONTROLPIPINGSCH...

Страница 11: ...30 175 5 45 Applies to 110998 series pilot valves only Differential Setting Chart Dash Dash Dash Dash Dash Load PSI Load PSI Load PSI Load PSI Load PSI Unload PSI Unload PSI Unload PSI Unload PSI Unload PSI 100 90 100 997 30 70 adjustable 998 71 150 adjustable 999 151 175 adjustable Customer to set see differential setting chart Additional factory preset valves are available upon request Dash Dash...

Страница 12: ...10832 or 110998 series to automatically regulate the passing of air tank pres sure to the unloading arrangement ContinuousRunOperation ContinuousRunOperation ContinuousRunOperation ContinuousRunOperation ContinuousRunOperation Suctionvalveunloaderassemblies arerecommended for use on Quincy compressors where the compressor is to run continuously and a constant pressure is to be maintained The purpo...

Страница 13: ...umber Number Description Description Description Description Description Recommended Spare Parts 1 110377E100 air filter element 1 114772 gasket set 1 116162X valve plate assembly LP 1 116163X valve plate assembly HP 1 116176 piston ring set LP 1 116177 piston ring set HP 1 114772 gasket set 1 116163X valve plate assembly HP 1 116162X valve plate assembly LP 1 110377E100 air filter element 1 11019...

Страница 14: ...unted units and base mounted units The parts listed here are for standard QT 10 units and may or may not be applicable to specially built units Check with your local authorized Quincy distributor for parts that can be used for custom built units Make sure the components you order are rated within the safe operating limits of your system If you are doubtful about which components to order contact y...

Страница 15: ...t units Check with your local authorized Quincy distributor for parts that can be used for custom built units Make sure the components you order are rated within the safe operating limits of your system If you are doubtful about which components to order contact your local Quincy distributor Pre formed discharge tubes are available Contact factory with model tank size information Part Part Part Pa...

Страница 16: ...ofcompletion EquipmentheldforBuyershallbeatBuyer sriskandstoragechargesmaybeappliedatthediscretion of Seller Accounts past due shall bare interest at the highest rate lawful to contract for but if there is no limit set by law such interestshallbeeighteenpercent 18 Buyershallpayallcostandexpenses includingreasonableattorney sfees incurred in collecting the same and no claim except claims within Sel...

Страница 17: ...eof must be promptly returned to seller freight prepaid for inspection Sellerwarrantsrepairedorreplacedpartsofitsownmanufactureagainstdefectsinmaterialsandworkmanshipunder normal use and service for ninety 90 days or for the remainder of the warranty on the product being repaired This warranty shall not apply and Seller shall not be responsible or liable for a Consequential collateral or special l...

Страница 18: ...s 217 222 7700 Air Master Air Master Air Master Air Master Air Master 217 277 0270 E mail E mail E mail E mail E mail info quincycompressor com W W W W Website ebsite ebsite ebsite ebsite quincycompressor com quincyairmaster com 2006 Quincy Compressor an EnPro Industries company All Rights Reserved Litho in U S A ...

Отзывы: