1. DELCOS 3100 Electronics
12
re 1.3 Menu structure
Menu prompting takes place in the 2nd line of the plaintext
field. To access the different menus, first press the
key.
You can move between the various menu branches using
the (left) and (right) keys.
Using the (up) and (down) keys, you can
retrieve/select the parameters in the various menu
branches.
The menus do not scroll through horizontally and
vertically, i.e. they are limited at either end.
Before you can change parameters, you may have to
enter a code, see Chapter 1.3.9.
The menu closes automatically two minutes after last
pressing a key
The following display values in the menus as well as the
overview merely serve as examples.
Danger
The machine can start at any time when changing
parameters in the standby mode.
1.3.1
[MAINTENANCE SCHED.] menu
Using the and keys, go to the [MAINTENANCE
SCHED.] menu option. This is where you can then
retrieve/select individual parameters using the and
keys.
The following parameter entries are stored under the
[MAINTENANCE SCHED.] menu heading and can also be
displayed there:
TOTAL RUNNING
12345 h
LOADED HOURS
10987 h
AIR FILTER IN
----- h
WATER FILTER IN
9999 h
MOTOR GREASING
9999 h
SHUTDOWN
DEACTIVATED
Note
Further information is provided in Chapter 1.6,
Maintenance Intervals.
The menu closes automatically two minutes after last
pressing a key.
1.3.2
[CONTROL MENU] menu
Using the and keys, go to the [CONTROL MENU]
menu option. This is where you can then retrieve/select
individual parameters using the and keys.
The following parameter entries or the following values
are stored under the [CONTROL MENU] menu heading
and can also be displayed there:
CUT-OUT POINT10.0 bar / 145 psi
CUT-IN POINT 9.5 bar / 138 psi
version FS only
TARGET PRESSURE9.5 bar/138 psi version RS,SR only
AUTOMATIC OPERATION
SPEED REGULATION ON
version RS only
VOL.MAX.
10.0 m3/min
version RS only
VOL.MIN.
2.0 m3/min
version RS only
DISPLAY UNITS =
m3/min
version RS,SR only
REMOTE CONTROL
ON
TIMER CONTROL
OFF
AUTO RESTART
OFF
POWER LOSS TIME
2 s
START-UP DELAY
5 s
DRYER PRE-RUN
0 min
RS485-PROTOCOL
ModBus
RS485-BAUDRATE
19200
NUMBER OF SLAVE
1
Note
Further information is provided in Chapter 1.7,
Operating modes.
The menu closes automatically two minutes after last
pressing a key.