![background image](http://html1.mh-extra.com/html/gardner-denver/delcos-3100/delcos-3100_user-manual_3571327004.webp)
Contents
2
1
DELCOS 3100 Electronics..................................................................................................................................................4
1.1
Foreword .......................................................................................................................................................................4
1.2
Controls .........................................................................................................................................................................4
1.2.1
Keypad...............................................................................................................................................................4
1.2.2
Light-emitting diodes.........................................................................................................................................5
1.2.3
Changing language...........................................................................................................................................6
1.2.4
Plaintext field - Line 1........................................................................................................................................6
1.2.5
Plaintext field – line 2, status display ..............................................................................................................6
1.3
DELCOS 3100 menu structure (example values).......................................................................................................9
1.3.1
[MAINTENANCE SCHED.] menu...................................................................................................................12
1.3.2
[CONTROL MENU] menu...............................................................................................................................12
1.3.3
[FAULT MEMORY] menu ...............................................................................................................................13
1.3.4
[LIMIT VALUES] menu....................................................................................................................................13
1.3.5
[OPTIONAL INPUTS] menu ...........................................................................................................................13
1.3.6
[WATER] menu ...............................................................................................................................................13
1.3.7
[TIMER CONTROL] menu ..............................................................................................................................14
1.3.8
Changing values .............................................................................................................................................15
1.3.9
Locking/unlocking code ..................................................................................................................................16
1.3.10
Setup code ......................................................................................................................................................16
1.4
Starting up ...................................................................................................................................................................17
1.4.1
Entering delivery rates (version RS only) ......................................................................................................17
1.4.2
Starting the system .........................................................................................................................................17
1.4.3
Control (version RS and SR only) ..................................................................................................................18
1.4.4
On-load/off-load operation ..............................................................................................................................18
1.4.5
Switching the system off .................................................................................................................................18
1.4.6
Faults/shutdown/power failures......................................................................................................................18
1.4.7
Warnings .........................................................................................................................................................18
1.4.8
Maintenance activities ....................................................................................................................................18
1.4.9
Group-fault relay..............................................................................................................................................19
1.4.10
Speed ON message (version RS only)..........................................................................................................19
1.4.11
Running-hours/loaded-hours counter ............................................................................................................19
1.4.12
Fault memory ..................................................................................................................................................19
1.5
DELCOS 3100 fault table in the case of a fault or warning ......................................................................................20
1.5.1
Check-list .........................................................................................................................................................20
1.5.2
Faults/warnings table ......................................................................................................................................20
1.6
Maintenance intervals.................................................................................................................................................32
1.7
Operating modes ........................................................................................................................................................32
1.7.1
Automatic and continuous operation..............................................................................................................32
1.7.2
Motor control operating modes (version RS only).........................................................................................32
1.7.3
Setting the volumetric-flow unit for the status display (version RS and SR only)........................................34
1.7.4
Speed limitation (version SR only) .................................................................................................................34
1.7.5
Remote control ................................................................................................................................................34
1.7.6
Changing over pressure by remote control ...................................................................................................34
1.7.7
Switching on-load/off-load by remote control (version FS only) ...................................................................35
1.7.8
Remote control for enabling on-load operation .............................................................................................36
1.7.9
Combined remote control of on-load/off-load operation and enabling of on-load operation
(version FS only) .............................................................................................................................................36
1.7.10
Automatic restart after power failure ..............................................................................................................37
1.7.11
Unlimited automatic restart after power failure..............................................................................................37
1.7.12
RS485 communication....................................................................................................................................37
1.8
Water circuit ................................................................................................................................................................38
1.8.1
Electrical equipment........................................................................................................................................38
1.8.2
Status display for water circuit........................................................................................................................38
1.8.3
Automatic water level regulation ....................................................................................................................38
1.8.4
Water exchange ..............................................................................................................................................39
1.9
Factory settings...........................................................................................................................................................39