Instructions
5
19
S
U
A
1800 909 909
www.globalpowerbrands.com email: [email protected]
AFTER SALES SUPPORT
43669
Clearing a blocked impeller/mulcher
WARNING.
Ensure the blower/vacuum ON/OFF switch is in the STOP (0) position
and the spark plug cover (8) is removed to prevent accidental starting which may
cause serious injury.
1. Switch the On/Off switch to the STOP (O) position. Wait for the impeller to stop
rotating.
2. Disconnect the spark plug cover (8) to prevent the unit from starting.
3. Remove the blower/vacuum tube and/or the vacuum bag.
4. Carefully remove the material blocking the tube or impeller. Inspect the blades
to ensure there is no damage. Rotate the impeller blades by hand to ensure the
blockage is completely cleared.
5. Reinstall the vacuum bag and blower/vacuum tube.
6. Reconnect the spark plug cover.
7. Empty the collection bag.
Use of the petrol blower vac
The GARDENLINE® Petrol Blower Vacuum can efficiently collect a wide variety
of debris ranging from grass clippings and leaves. Debris should be collected or
vacuumed in a dry condition. As a general rule try to operate the blower vacuum
at the lower throttle setting necessary to get the job done.
• Prior to use of the blower vacuum ensure you have read and understood this
instruction manual.
• Ensure you are wearing suitable clothing and also safety equipment like safety
glasses, ear protection and a mask if necessary.
• Keep a gap between the air intake and clothing and body parts as this will reduce
the performance and may result in injury.
Emptying the collection bag
The collection bag should be emptied as soon as a noticeable reduction in
performance of the vac is noticed. In general it is suggested to empty the bag
when it becomes 1/2 full so as to keep the overall weight down and also to
maintain max performance.
When emptying the debris bag it is suggested to wear a face mask and eye
protection.