Instructions
5
• Mix only enough fuel for your immediate needs. If fuel must be stored longer
than 30 days, it should first be treated with a stabilizer or similar product.
Operation
During operation of the blower it is recommended to wear eye protection, a dust
mask, and full hearing protection.
Choke control
If the engine is cold you will need to use the choke control.
Start position (choke closed).
Run position (choke open).
Starting the blower
To start the engine, proceed as follows:
1. Press the primer (9) 5 to 10 times or until
there are no air bubbles are visible in the
fuel discharge line.
Note.
This is not necessary if the engine
is warm.
2. If the engine is cold, move the choke (15) lever upwards closed.
Note.
Again this is not necessary if the engine is warm.
3. Press the I symbol on the On / Off switch to turn the ignition ON.
4. Place the blower vac on the ground and hold the blower vac handle firmly with
your left hand.
5. Pull the recoil starter (6) until the engine
sounds like it wants to run or starts.
6. Slowly move the choke lever halfway
down. If the motor is not running re try to
start in the half way choke position.
7. Allow the motor to run for approx 20 sec
in the half choke position and then slowly
move to the full run position.