TR-HT2xx LED Controller - User Manual
Event number
Reason
1 to 127
An error has occurred. See Section 13.2.6, Error
codes.
128
A light has been connected and is working.
129
A light has been connected but does not have a
current or voltage rating.
130
An over temperature error has occurred.
131
An over current error has occurred.
132
An error has occurred while autosensing the rating
of a light.
138
SafePower trainup has completed.
139
SafePower trainup has failed or been cancelled.
140
In switched mode, the light has been turned off
because the duty cycle is too high.
13.2.6 Error codes
Some error codes are displayed on the TR-HT's front panel: these are also
shown.
Error number
Reason
Err 1
A parameter value is invalid.
Err 2
Command not recognised.
Err 3
A numeric value is in the wrong format.
Err 4
Wrong number of parameters.
Err 5
This is a warning, not an error. One of the
parameters is out of range and the value of that
parameter has been adjusted. For example,
sending an
RT
command with a delay of 0μs returns
an ‘Err 5’. The command is accepted, but the delay
is set to the minimum allowed value.
—
74
—