TR-HT2xx LED Controller - User Manual
12.3.4 Trigger timing commands
These commands are for use with the TR-HT's digital inputs and outputs
which are described in
Section 8, Digital inputs and outputs
.
Show status
ZZ
This command shows the operational parameters of teh digital
outputs. A typical output for the TR-HT controller is:
Encoder:1 line
OP1: MD=2, IP=1, GT=-, DL= 10.000ms, PL=
2.000ms, RT= 0.000ms, IoGefrp
OP2: MD=5, IP=2, GT=-, DL= 0.000K, PL=
0.001K, RT= 0.000K, iogefrp
Where:
OP
output channel number
MD
mode for the output
IP
input used for triggering
GT
gate input for enabling or disabling the output
DL
pulse delay
PL
pulse width
RT
retrigger delay
iogefrp
flags used by output.
Set the output mode
This command sets the configuration for an output channel. See
for a description of these parameters.
ZSc,m,i,g,f
Where:
c
=
output channel (1 to 2)
m
=
mode (0 to 7)
i
=
trigger input:
0 for free running timer
1 to 4 for IP1 to IP4
5 to 6 for OP1 to OP2
—
65
—