WWW.STEMMER-IMAGING.COM
TR-CL180 Lens Controller - User Manual
Save the settings to memory
AW
This command saves the settings to non-volatile memory. If you
power cycle theTR-CL180 before sending the
AW command, all
changes are lost and the unit returns to the values set before the last
AW command.
Clear configuration
CL
This command clears the configuration and lighting ratings, and
turns the output off. The results of any
VL, RS, RW, RU, RA, RE, RP,
and
AW commands are cleared.Show configuration
This command shows the configuration of the TR-CL180. Type in:
ST
A typical reply to this command might be:
CH1,MD0,AF 3.95, IF 0.00,
IP1,FL0,Mn0.0,Mx0.
Where :
CH
Channel number; this is always 1.
MD
Mode: 0 = continuous, 1 = switched, 2 = analog.
AF
Active optical power in the range of the connected
lens.
IF
Idle optical power in the range of the connected lens.
IP
Always returns IP1
RT
Retrigger delay.
IP
Always returns IP1.
FL
Flags set using the RE1 command.
Mn
In Analog mode, the voltage corresponding to
minimum focus.
Mx
In Analog mode, the voltage corresponding to
maximum focus.
—
30
—
WWW.STEMMER-IMAGING.COM