Summary of Contents for PP600F

Page 1: ...SER MANUAL PP600F PP602F PP610F PP612F LED Lighting Controllers Revision 10 Gardasoft Vision Ltd Trinity Court Swavesey Cambridge CB24 4UQ UK Tel 44 1954 234970 Fax 44 1954 231567 Web www gardasoft co...

Page 2: ...2...

Page 3: ...user must ensure that incorrect functioning of this equipment cannot cause any dangerous situation or significant financial loss to occur Gardasoft Vision Ltd and Gardasoft Products Ltd will not acce...

Page 4: ...how to send RS232 commands Mount the PP600F as described in Mechanical Fixing using a DIN rail or the mounting holes In particular read the notes on heatsinking Set up the PP600F for the desired opera...

Page 5: ...reatly increase resulting in a further rise in temperature 3 1 3 Electrical The user must ensure that the potential difference between any combination of applied signals does not exceed the supply vol...

Page 6: ...en Wird pro Kanal mit hohen Blitzspannungen und kurzen Blitzzeiten gearbeitet steigen die Temperaturen nochmals an 4 1 3 Elektrischer Betrieb Stellen Sie sicher dass die Spannungsdifferenz bei keiner...

Page 7: ...operation are provided separately for each channel Continuous In continuous mode the output is a continuous current Selected Continuous In selected continuous mode one or both inputs can be used to se...

Page 8: ...This is the voltage applied between the anode and cathode of each optically isolated input Input disable level IPL IPL 1 V Output current per channel il 4A continuous or 10A pulsed Maximum allowed cur...

Page 9: ...r space between the PP600 and any parts which could be affected by high temperatures The enclosure of the PP600 is used to dissipate power in the form of heat For this reason the material to which the...

Page 10: ...inimum value required by the LED light and the PP600 together Chose a PSU that limits its output current by design by setting the current limit on the supply if this feature exists or use fuses Rememb...

Page 11: ...ply connection On previous revisions of this product the case was connected to GND The input connector has connections as follows Screw Terminal ID Function IP1 Input 1 positive IP1 Input 1 negative I...

Page 12: ...3 RX input to PP610 5 GND 8 1 3 PP602F and PP612F CCS Connector Refer to section 12 for details on connecting to CCS lighting 8 2 Power Supply The PP600 has split power input connectors for the contro...

Page 13: ...nd connections and VS connections are commoned 8 2 2 Split Supply Applications It is possible to run the two channels and digital system from two or three separate supplies as shown below though this...

Page 14: ...splay COLD for about 10 seconds while the memory is cleared 9 3 Set Up Each channel of the PP600 can operate in three ways Continuous output The output current is fixed Selected continuous output One...

Page 15: ...UT2 1 Current setting 2 SE12 INPUT2 0 INPUT1 0 Current setting 1 INPUT2 0 INPUT1 1 Current setting 2 INPUT2 1 INPUT1 0 Current setting 3 INPUT2 1 INPUT1 1 Current setting 4 9 3 2 Pulsed Output The out...

Page 16: ...channel The PP600 will then ensure that the current averaged over approximately 200ms to the LEDs does not exceed the rating If the rating is exceeded the output is turned off and the display shows E...

Page 17: ...CON Use UP or DOWN to select the required current in amps Note that the units digit is flashing and that UP or DOWN change the value by one Pressing RANGE to make the tens digit flash causes the value...

Page 18: ...wo Pressing RANGE to make the tens digit flash causes the values to change by ten The hundreds and thousands digits can also be selected using range The PP600 is ready to pulse the output on a trigger...

Page 19: ...ded Set Up allows all the features of the PP600 to be set up It is entered by holding the RANGE button down for one second In order for the whole range of timing values to be entered it is necessary t...

Page 20: ...mps Then press SELECT to set the output current The RANGE button changes which digit is altered Press SELECT Wait one second Press SELECT Wait one second Press SELECT Press SELECT Press SELECT Wait on...

Page 21: ...text Use UP or DOWN to select the required delay in milliseconds Note where the decimal point is and that the delay is set up in multiples of 1us Note that the units digit is flashing and that UP or D...

Page 22: ...the command Some commands need the output or input channel to be specified For these the channel number either 1 or 2 immediately follows the two letter command Where more parameters are needed they c...

Page 23: ...e AW command has been issued 10 1 1 General Commands AW Save the settings to memory Syntax AW Once the settings are saved to memory they are then retained when the unit is switched off If this is not...

Page 24: ...35A for 100ms using input 1 as trigger and a delay of 15ms with a debounce period of 20ms The result of the ST command will be 01 M 06 E 1000 V 0 2 25 7 500 1500 02 M 01 E 7000 V5350 0 D 15 0 P 0 10...

Page 25: ...ed leave the Ee off the command Example of Continuous Output Mode Set a continuous current of 0 5A on output channel 1 RS1S0 Select continuous current RC1C0V500 Current 500mA 10 1 3 Selected Continuou...

Page 26: ...ection RC1C0V0 2 Current0 0 25mA When input 1 is 0 and input 2 is 0 RC1C1V25 7 Current1 25 7mA When input 1 is 0 and input 2 is 1 RC1C2V500 Current2 500mA When input 1 is 1 and input 2 is 0 RC1C3V1500...

Page 27: ...44 Bad channel number 45 Channel number trigger input mismatch 46 Invalid delay for programmed current 47 Invalid pulse width RC Set the output current for the selected channel Syntax RCfCcVvEe Where...

Page 28: ...ayout Connector Channel Use SKT9 1 CCS 12V lights SKT10 1 CCS 24V and HLV lights SKT12 2 CCS 12V lights SKT11 2 CCS 24V and HLV lights 12V lights always have a 2 pin connector 24V and HLV lights alway...

Page 29: ...input voltage of 18V to 24V A trigger input of only 5V will result in approximately an additional 8us delay The repeatability of the pulse delay is 1 microsecond and of the pulse width is 0 1 microsec...

Page 30: ...The PP600 is calibrated during manufacture This stored calibration has become invalid Make a note of the number and contact your distributor E 00 E 01 E 02 E 03 E 04 E 05 E 06 E 07 E 18 E 42 E 43 A ha...

Page 31: ...31...

Page 32: ...ting clip for PP500 and PP500F ranges PP500F Range Same as the PP500 range but with fast pulsing Pulse delay from 10us to 9 9ms in 1us steps Pulse width from 1us to 9 9ms in 1us steps PP500F Lighting...