8
Connections
8.1
General
All connections except RS232 are available on screw terminals. The opto-
isolated inputs require a voltage between 4.5v and 24v DC for a positive logic
level. Open circuit or less than 1v gives a negative logic level.
The case of the PP600 is not connected to the GND
supply connection. On previous revisions of this
product the case was connected to GND.
The input connector has connections as follows:
Screw Terminal ID
Function
IP1+
Input 1 positive
IP1-
Input 1 negative
IP2+
Input 2 positive
IP2-
Input 2 negative
The power connector has the following connections:
Screw Terminal ID
Function
GND1
C
H
A
N
N
E
L
1
POWER SUPPLY (-)
VS1+
POWER SUPPLY (+)
LD1+
LOAD (+)
LD1-
LOAD (-)
VS+
DIGITAL
POWER
SUPPLY (+)
GND
DIGITAL
POWER
SUPPLY (GND)
LD2-
C
H
A
N
N
E
L
2
LOAD (-)
LD2+
LOAD (+)
VS2+
POWER SUPPLY (+)
GND2
POWER SUPPLY (-)