21
Extended Set Up can be used to set pulsed output as follows.
PP600 is ready
Use UP or
DOWN to
select "PU 1"
for channel 1 or
or "PU 2" for
channel 2
The PP600 is ready to
pulse the output on a
trigger.
Use UP or DOWN to select
which output channel to set up -
"CH1" or "CH2".
Press and hold RANGE
for one second
Press SELECT
Press SELECT
Wait one second
Press SELECT
Press SELECT
Wait one second
Use UP or DOWN and RANGE
to set the maximum current
rating of the LED unit. See text.
Use UP or DOWN to select the required delay in
milliseconds. Note where the decimal point is
and that the delay is set up in multiples of 1us.
Note that the "units" digit is flashing and that UP
or DOWN change the value by two. Pressing
RANGE to make the "tens" digit flash, causes
the values to change by ten. The "hundreds" and
"thousands" digits can also be selected using
range.
Press SELECT
Wait one second
Set the pulse width in the same way as the delay.
Press SELECT
Press SELECT
Select "0" for amps or "-3" for milliamps. Then
press SELECT to set the pulsed current. The
RANGE button changes which digit is altered.
Wait one second
Press SELECT
Press SELECT
Wait one second