User module »DP-HR-U-CON-2«
91
· Target and user modules (DP-HR-U)
Main power supply
Type:
Internal power pack
Connection:
1 × IEC plug (IEC-320 C14)
Power input:
100 - 240 VAC; 0.6 A - 0.3 A
Redundant
power supply
optional
Type:
Portable power pack
Connection:
1 × Mini-DIN 4 socket (Power In)
Power input:
12 VDC; 2.3 A
Casing
Material:
Anodised aluminium
Dimensions (W × H × D):
210 × 44 × 210 mm
Weight:
Approx. 1.3 kg
Operating
environment
Temperature:
+5 °C to +45 °C
Air humidity:
20 % to 80 %, non-condensing
Storage
environment
Temperature:
-20°C to +55°C
Air humidity:
15 % to 85 %, non-condensing
Conformity
CE, EAC, FCC Class B, RoHS
DP-HR-U-CON-2
Summary of Contents for DP-HR-CON