Target module »DP-HR-U-CPU-DH-UC«
65
· Target and user modules (DP-HR-U)
DP-HR-U-CPU-DH-UC
Audio
Transmission type:
transparent, bidirectional
Resolution:
24 Bit
Refresh rate:
96 kHz
Bandwidth:
22 kHz
USB
Specification:
USB 2.0
Transmission type:
transparent
Transmission rate:
Max. 16 Mbit/s
Power supply
Type:
Portable power pack (12 V/2 A)
Connector:
1 × Mini-DIN 4 socket
Power input:
Max. 700 mA
Housing
Material:
Anodised aluminium
Dimensions (W × H × D):
105 × 26 × 164 mm
Operating
environment
Temperature:
+5 °C to +45 °C
Air humidity:
20 % to 80 %, non-condensing
Storage
environment
Temperature:
-20°C to +55°C
Air humidity:
15 % to 85 %, non-condensing
Conformity
CE, EAC, FCC Class B, RoHS