Target module »DP-HR-U-CPU-MC2-UC«
27
· Target and user modules (DP-HR-U)
DP-HR-U-CPU-MC2-UC
Power supply
Type:
Portable power pack (12 V/2 A)
Connector:
1 × Mini-DIN 4 socket
Power input:
Max. 1.2 A
Housing
Material:
Anodised aluminium
Dimensions (W × H × D):
105 × 46 × 164 mm
Weight:
Approx. 580 g
Operating
environment
Temperature:
+5 °C to +45 °C
Air humidity:
20 % to 80 %, non-condensing
Storage
environment
Temperature:
-20°C to +55°C
Air humidity:
15 % to 85 %, non-condensing
Conformity
CE, EAC, FCC Class B, RoHS
Summary of Contents for DP-HR-CON
Page 1: ...A9200141 1 30 G D Target and User Modules Installation and Operation DP HR U variants EN...
Page 194: ......
Page 195: ......