© Galvin Engineering Pty Ltd
Product Installation Guidelines
Version 1, 19 October 2022, Page
3
of
25
4.1
TECHNICAL DATA
Inlet
/ ” Cu Tu e
Outlet
Flow Straightener
Headwork
Thermostatic mixing valve
Solenoid
Mains Powered (Transformer)
90
– 264V - 47/63Hz 0.15A
6.75V DC
– 0.5A
0.7m
Finish
Chrome
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice.
Table 1
. Technical information
4.2
SENSOR DETAILS
Input Voltage
6.75V DC
– 0.5A
Sensor function
Proximity
Pre-set line purge feature interval:
72 hours after last flush, water flow duration 60 sec
Pre-set continuous run:
10 min
5.0
WATER SUPPLY CONDITIONS
5.1
INTRODUCTION
This thermostatic mixer with proximity sensor is manufactured to the highest standards and has approval to
AS4032.4 which permits it to be installed in healthcare establishments such as hospitals, nursing homes and
residential care homes. When installed in healthcare establishments the supply conditions detailed in
must be observed and the commissioning and servicing requirements detailed on section 8.0 & 10.0
must be
followed.
5.2
SUPPLY PRESSURE REQUIREMENTS
This mixer is designed to be installed on all types of plumbing systems. Hot and cold water supply pressures
should be reasonably balanced; however, the mixer will function within specification on unequal pressures up
to 10:1. The mixer has integral isolating valves which permit servicing of the strainer, check valve/flow regulator
and thermostatic cartridge. They are also used for thermal disinfection. The minimum pressure for the correct
thermal operation is 30kPa. However, to achieve an acceptable flow performance at very low pressures it may
be necessary to remove the combined check valve and flow regulators and replace them with simple check
valves to facilitate thermal disinfection.
Working Temperature Range (°C)
Min
5
Max
80
Minimum Temperature Differential (between the supply and the outlet temperature) (°C)
Min
10
Adjustable Temperature Range (°C)
Min
35
Max
45
Working Pressure Range (kPa)
Min
30
Max
500
Permitted Supply Pressure Variation
10:1
Factory Set Thermostatic Temperature (°C)
41
Maximum Thermostatic Temperature (°C)
45
Nominal Flowrate (LPM)
8
Table 2
. Water supply conditions
Note:
Tapware must be installed in accordance with the provisions of AS/NZS 3500. Installations not complying with
AS/NZS 3500 may void the product and performance warranty provisions.