Module A
Module B
Module C
Column
Side
1
3
5
2
4
6
1
2
5
6
4
3
Valves
Module
V1 and V2
A
V3 and V4
B
V5 and V6
C
PE: Protective Earth;
BK: Black;
BN: Brown;
GY: Grey.
• Route the solenoid valves cables (1 - 6) through the cable clips provided into the Ex
e enclosure through the glands indicated in the following image.
Figure 17. Solenoid Valves Cable Distribution
• Connect the solenoid valve cables inside the Ex e enclosure according to the wiring
guide decal located inside the enclosure cover.
Figure 18. Wiring Guide Decal
• Attach the Ex e enclosure to the sump box using the supplied mounting bracket and
bolts. Ensure the cables are tidy using the cable clips on the sump wall.
• Run the 18 core cable through the cable duct up to the bottom of the head cabinet.
• Run the encoder cables through the cable duct to the Multiplexer board located
under the head cabinet.
2A03229 APOLLO 3000L Installation and Commissioning Manual Issue 1
20
APOLLO 3000L INSTALLATION