jubilee clip
vapour hose
fuel delivery pipe
vapour pipe
manifold
cap
screws
splitter
bracket
backing
plate
coaxial
adaptors
splitter bracket cover
securing
brackets
splitter bracket
viewed from above
soffit panel
backing plate
cap screws
2.2 Hydraulic Installation
2.2.1 Connecting the Coaxial Adaptors and Hoses
Coaxial hoses connect to coaxial adaptors in which the returned vapour is directed to
the vapour return hoses.
To protect hose fittings, the VR2 version has splitter brackets with covers that enclose
the coaxial adaptors.
Each splitter bracket is fixed to the soffit panel using three capscrews and a backing
plate. The splitter bracket is used as a template for drilling the required holes in the
soffit panel.
Figure 28. Coaxial Adaptors and Splitter Bracket
The overall process is:
(a) Fit the soffit panel to the dispenser;
(b) Locate splitter brackets and locate holes for backing plate;
(c) Remove soffit;
(d) Drill holes and fit bracket and backing plate using capscrews;
Figure 29. Fitting of Bracket and Backing Plate to Soffit Panel
2A03229 APOLLO 3000L Installation and Commissioning Manual Issue 1
28
APOLLO 3000L VR2 COMPONENTS INSTALLATION