6.
Apollo 3000 Set Up Procedure Standard Fuel
1.
Set Up Addresses Dip Switches
Set addresses on AC Control PCB as shown in table below
Note AC Control Boxes number from right to Left as viewed with Column on your left, refer
Apollo 3000 Hydraulic & Intrinsic Connections layout Section Pg. 28 & 29
Box no.
Dip Switches
4 3 2 1
A
on on on off
B
on on off on
C
on on off off
2.
Preset Display PCB Dip Switch Setting
3 Product front = 3,5 & 12 are on rest are off
3 Product rear = all set off
3.
Power up
Apply Power, for Software Version VA 2.21 & > listen for single beep -pause-single- followed
by six short beeps
Displays should show as follows
FRONT
Pn - A
REAR
Pn - b
Fn - _ _
Fn - _ _
Note if you get FUEL OFF then toggle Managers Switch to get required display.
4.
Setting Hoses Active.
Empty RAM by Switching managers Swt. & pressing Service Agent Button, enter 10-Fill-Fill .
wait for Displays to return as per above.
Activate as follows.
Hose F1 = Enter 22-Fill-1-Fill
Hose R1 = Enter 23-Fill-1-Fill
Hose F2 = Enter 42-Fill-1-Fill
Hose R2 = Enter 43-Fill-1-Fill
Hose F3 = Enter 62-Fill-1-Fill
Hose R3 = Enter 63-Fill-1-Fill
5.
Check Pricing Displays read as indicated on Graphic Panel
Cents per Litre = “0.0” for Cents & Dollars per Litre = 0.000 for Dollars
Refer PEC Manual 87372 section “Dip Switch Settings Multipec” for corrections
Set Product Price
Product A = Enter 31-Fill-$ amount (eg 993-Fill = 99.3c)
Product B = Enter 51-Fill-$ amount-Fill
Product C = Enter 71-Fill-$ amount-Fill
Note To test Comms. And Console control is working correctly, enter a non real price for each product
and then switch unit over to Console control price should then change as set on console. Check both
sides
6
Pump Number (Comms. Connection)
To connect to Console unit has to be numbered both front & rear.
To number Front Enter 20-Fill (Display shows PF-00)
Enter Required # (Display shows = PF- (number entered)- enter Fill
To number Rear Enter 21-Fill (Display shows = PF-00)
Enter Required # (Display shows = PF- (number entered)- enter Fill
Switch Managers Switch to normal
Note (#) = Pump/Console number
Summary of Contents for Apollo 3000
Page 1: ...Apollo 3000 Set up Installation Parts Manual...
Page 2: ......
Page 4: ......
Page 15: ...11 Float Switch 89778 Float Swt Mtg Angle only 89749 Float Switch Bracket Assembly...
Page 26: ...22 Stage 1 Installation Procedure Sump Column Position Fig 2...
Page 27: ...23 file gme c docum pec apollo2 fig 2 manual doc Stage 1 Installation Service Area Spec Fig 3...
Page 28: ...24 Stage 1 Installation Procedure Mounting Positions Fig 4...
Page 29: ...25 Stage 3 Vent Box Installation Vent Box Position Sealing Spec Fig 5...