27.
Comms Channel B errors
70
Channel B Receiver Parity Error
Error 70 indicates a parity error was detected in one or more of the received message bytes.
71
Channel B Receiver Framing Error
A character was received for which no stop bit was detected.
72
Channel B Receiver Break Error
A steady low (space) signal has appeared at a receiver, indicating a break condition at the
transmitting end. The formal definition is that an all zero character with no stop bit has been
received.
73
Channel B Receiver Overrun Error
This indicates an overflow of the 3 byte FIFO buffer for a receiving channel. This means that the
processor is not reading the incoming data fast enough to prevent overwriting this stack.
74
Channel B Receiver Checksum Error
The message received had a checksum error.
75
Channel B Receiver Data Error
This indicates that the polling message received from the Input Processor is an invalid type (or
that the comms line has been corrupted, in which case a checksum error will probably also occur).
76
Channel B Receiver Overflow Error
The message received was too long for the buffer. This may happen if no EOM character or
sequence is detected.
77
Channel B Transmitter Overflow Error
The transmitter has tried to send a message which is too long. This means that the transmit buffer's
last position was reached, but an EOM character or sequence was not present.
78
Channel B Receive Timeout Error
This indicates that the receiver is expecting a character from the Input Processor, but has not
received one for more than 1 second.
79
Channel B Transmit Timeout Error
This indicates that the transmitter is attempting to send a message to the Input Processor, but there
has been a delay of greater than 1 second since the last character was transmitted.
Summary of Contents for Apollo 3000
Page 1: ...Apollo 3000 Set up Installation Parts Manual...
Page 2: ......
Page 4: ......
Page 15: ...11 Float Switch 89778 Float Swt Mtg Angle only 89749 Float Switch Bracket Assembly...
Page 26: ...22 Stage 1 Installation Procedure Sump Column Position Fig 2...
Page 27: ...23 file gme c docum pec apollo2 fig 2 manual doc Stage 1 Installation Service Area Spec Fig 3...
Page 28: ...24 Stage 1 Installation Procedure Mounting Positions Fig 4...
Page 29: ...25 Stage 3 Vent Box Installation Vent Box Position Sealing Spec Fig 5...