Command format
SOUT0 EMode,EImpT,EImpC,DMode,DImpT,DImpC,AMode,AImpT,AImpC,ADelay
Parameters
EMode
– output operating mode by arming:
0 – no reaction,
1 – output is inverted,
2 – output generates pulses,
EImpT
– pulse time during Arming, msec.
EImpC
– number of pulses
during Arming.
DMode
– output operating mode by Disarming:
0 – no reaction;
1 – output is inverted;
2 – output generates pulses.
DImpT
– pulse time
during Disarming, msec.
DImpC
– number of pulses
during Disarming
AMode
– output mode by Alarm:
0 – no reaction;
1 – output is inverted;
2 – output generates pulses.
AImpT
– impulse time
during Alarm, msec
AImpC
– number of impulses during Alarm.
ADelay
–
activation delay after Alarm mode is on, in sec.
The Device rounds off pulse duration to 0.1 sec
Explanation
Setting the behavior of an output in signaling mode.
Example
Request: SOUT0 2,1,1,2,2,2,1,0,0,20
Reply:
SOUT0:EMode=2,EImpT=1,EImpC=1,DMode=2,DImpT=2,DImpC=2,AMode=1,
AImpT=0,AImpC=0, ADelay=20;
sout1, sout2, sout3 commands are similar to sout0.