DMC-40x0 Command Reference
DT • 85
CD
400,200
;
'Countour Data pre-loaded in buffer
CD
200,100
;
'Countour Data pre-loaded in buffer
CD
300,50
;
'Countour Data pre-loaded in buffer
AI
-1
;
'Wait for Analog input 1 to go low
DT
8
;
'Set positive DT to start contour mode
CD
0,0,0,0=0
#Wait
;JP
#Wait
,
_CM
<>511
;
'End of Contour Buffer/Sequence
;
'Wait until path is done
EN
;
'End program