250
●
VE
DMC-40x0 Command Reference
VE
FUNCTION:
Vector Sequence End
DESCRIPTION:
VE is required to specify the end segment of a coordinated move sequence. VE would follow the
final VP or CR command in a sequence. VE is equivalent to the LE command.
The VE command will apply to the selected coordinate system, S or T. To select the coordinate
system, use the command CAS or CAT.
ARGUMENTS:
VE n
No argument specifies the end of a vector sequence
n = ? Returns the length of the vector in counts.
USAGE: DEFAULTS:
While Moving
Yes
Default Value
-
In a Program
Yes
Default Format
PF
Command Line
Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_VEn contains the length of the vector in counts for the specified coordinate system, S or T.
RELATED COMMANDS:
Vector Mode
Vector Speed
Vector Acceleration
Vector Deceleration
Vector Position
Begin Sequence
CS
Clear Sequence
EXAMPLES:
#A
;
'Program Label
VM
AB
;
'Vector move in AB
VP
1000,2000
;
'Linear segment
CR
0,90,180
;
'Arc segment
VP
0,0
;
'Linear segment
VE
;
'End sequence
BG
S
;
'Begin motion
AM
S
;
'Wait for VE to execute in buffer
EN
;
'End program