GALA SYNERGIC 5000
18
3.7.2. USER PROGRAM JOB REPRODUCTION.
The user program welding situation is identified by LD25 led (JOB) lighting up. If we are in welding mode
(LD25 off) proceed to briefly press pushbutton P7, the LD25 led will light up, we are in JOB mode.
USER PROGRAM JOB REPRODUCTION.
D1
P1
)
D2
P7
P2
LD25
V
U
4
m/min
10
16
7
13
19
1
1- If LD25 is off, briefly press the JOB pushbutton
(P7), the LD25 led lights up, we are in JOB mode.
2- If, after pressing the JOB pushbutton the
message “no Job” appears on displays D2 and D1,
the system will automatically return to the welding
mode as this message is indicative of the fact. that
there is no user program recorded.
3- If there are welding programs recorded, the user
program no. used the last time will appear on display
D2; with pushbuttons P1 and P2 we can access
another different program no.
4- After selecting the welding program we will place
selector switches V-U as shown in display D1. The
welding action will not be possible until the selector
switches V-U are positioned as indicated on this
display.
5- Place the wire-feed speed control in its
intermediate position, (point “0” of the inner dial). At
this point the system will assign the appropriate wire
speed for the user program no. (JOB) selected.
Depending on the welding conditions, this wire speed
can be adjusted very accurately. Wire speed regulation
indicated by means of the INNER dial.
Intermediate position “0”: Speed recorded in JOB.
Rotation to the RIGHT of position “0”: Percentage
INCREASE of synergic speed.
Rotation to the LEFT of position “0”: Percentage
DECREASE of synergic speed.
The exact value of the wire speed can be read on
display D2 (Select with P3, m/min).
Notes:
a)- If the JOB no. corresponds to a user program that was recorded based on a synergic program the
welding power can be increased or decreased by means of selector switches V-U once the first welding
operation has been carried out. The system will assign the appropriate wire speed for the position chosen.
b)- We can change the JOB setting parameters; these are recorded in the user program, (see section 3.6),
and are exclusive parameters of the program selected.
3.7.3. DELETING OF ALL JOB PROGRAMMES.
An existing JOB program can be individually deleted by overwriting a new one over the top of it.
To delete all the user programs recorded in the memory, the equipment must be switched on (using O/I
on/off switch) keeping pushbutton P7 JOB) pressed; following the initial check process the message: “no Job”
will appear on displays D2/D1, defining that all the user programs have been deleted.