GALA SYNERGIC 5000
16
D2
D1
"
"
P1
P2
"
tOn
: Welding time in spot and intermittent welding operation.
Define the execution time of spot welding.
This parameter define the time in which the weld is activated in case of
intermittent welding mode.
Factory value: 2.0 s.
By pressing P1 we increase the value; máximum: 5 s.
By pressing P2 we decrease the value; minimum: 0.2 s.
"
"
P1
P2
"
tOFF:
Stop time on intermittent welding mode.
We use this parameter to define the time of the welding stop cycle.
Factory value: 0.8 s.
By pressing P1 we increase the value; máximum: 3.0 s.
By pressing P2 we decrease the value; minimum: 0.1 s.
"
"
P1
P2
"
tPrF
: Gas pre-flow time.
We define with this parameter the time in which the shielding gas is
flowing by the torch before beginning the welding operation.
Factory value: 0.3 s.
By pressing P1 we increase the value; máximum: 3.0 s.
By pressing P2 we decrease the value; minimum: 0.0 s.
"
"
P1
P2
"
tPSF
: Gas pre-flow time.
We define with this parameter the time in which the shielding gas is
flowing by the torch after finishing the welding operation.
Factory value: 0.5 s.
By pressing P1 we increase the value; máximum: 5.0 s.
By pressing P2 we decrease the value; minimum: 0.0 s.
"
"
P1
P2
"
FdC
: Wire approach speed. LIFT-ARC control.
This permits defining the approach speed, expressing it in a percentage
over the rated welding speed. We determine the lift-arc goodness with
the approach speed control.
Factory value: 36%.
By pressing P1 we increase the value; máximum: 100%.
By pressing P2 we decrease the value; minimum: 10%.
"
"
P1
P2
"
tbb
: Automatic burn-back time correction. Final wire length control.
When welding ends, there is a delay between the braking of the wire
drawing motor and the disappearance of the welding voltage (burn-
back time).
Factory value: 0.0 (Automatic delay time).
By pressing P1 we increase the value; máximum: 0.2 s (shorter welding
wire)
By pressing P2 we decrease the value; minimum: -0.2 s (longer welding
wire)
"
"
P1
P2
"
rEFr
: Torch cooling mode (see section 3.3.2).
It define the cooling mode;
AUT: Water cooling mode. The cooling system automatically switching-
off 2 minutes after the welding operation.
ON: Water cooling mode. Continuous cooling.
OFF: Mode without water cooling. Pressure protection disabled.