GALA SYNERGIC 5000
15
3.6. SETTING MODE OF CYCLE PARAMETERS.
In cycle parameter setting mode we can adapt the most outstanding variables that intervene in the welding
cycle to our needs.
3.6.1. OPERATING OF CYCLE PARAMETERS SETTINGS MENU.
The cycle parameter setting process is carried out as follows:
1º
2 s.
"
D2
D1
Keep pushbutton P6 (MODE) pressed for 2 sec. You will
enter the cycle variables setting menu. The indication “ton”
appears on display D2 if it is set at spot or interval welding
or “tPrF” (if it is set at continuous welding). The value of the
assigned parameter appears on display D, so in the case of
the left ton (welding time) a value of 2 sec. is assigned.
2º
"
By briefly pressing pushbutton P6 (MODE) the variable will
be changed on the setting menu; in the case of the left one
when pressing mode, we have changed from the “ton”
variable to the tPrF (preflow time) variable. The parameter
value assigned to this variable is 0.30 sec.
3º
"
P1
P2
"
With pushbuttons P1 and P2 we can increase or decrease,
respectively, the value of the variable assigned on the
setting menu.
In the case of the left one, with P1 we can increase the
preflow time value “tPrF” from 0.30 to 0.80.
3.6.2. VARIABLES OF CYCLE PARAMETER SETTING MENU.
The table below sums up the variables of the setting mode menu. The Factory value corresponds to the
value of the variable when it leaves the factory.
PARAMETER DESCRIPTION
ADJUSTABLE VALUE
FACTORY VALUE
Welding time (sport/ intermittent welding operation)
0.2÷5.0 s.
2 s.
Stop time on intermittent welding.
0.1÷3.0 s.
0.8 s.
Gas pre-flow time.
0÷3.0 s.
0.3 s.
Gas post-flow time.
0÷5.0 s.
0.5 s.
Approach speed.
10 ÷100% Vh
33% vh
After-burning time.
AUT ± 0.2 (s)
AUT
Cooling mode
AUT/ON/OFF
AUT
The time in approach process (Limited).
NOT ADJUSTABLE
VALUE
5 s max.
Time of interrupted cycle (Limited)
NOT ADJUSTABLE
VALUE
4 s max.
Cooling disconnection time (AUT Mode)
NOT ADJUSTABLE
VALUE
120 s.
If you wish to change the factory values of the setting menu;
"
P1
P2
"
2 sg
A moment may come about when you wish to delete the setting made
and recuperate all the factory values of the configuration menu. To do
this you must press pushbuttons P1 and P2 for two seconds. The
process ends when “FAct” appears on the display.
These factory values are only recuperated in manual welding mode
and by synergic programme. In JOB mode the setting parameters
will preserve the values they were recorded at.